INSTALLER: Leave these instructions with the appliance this terminal is serving.
CONSUMER: Retain these instructions for future reference. These instructions are to be used in conjunction with the
The GPV is a Direct Vent Terminal
designed to allow installation of
gas appliances where typical vent
configurations cannot be achieved.
GENERAL INFORMATION
These installation instructions must be used in conjunction with the
appliance and appropriate PVA adapter kit installation instructions.
Clearances listed in these instructions supersede those in the
appliance's installation instructions.
Power venting of direct vent appliances may result in the reduction
of efficiencies by as much as ten percent. Consider this in making
any venting and heating decisions in any installation application.
Selecting and installing the appliance
When selecting a gas appliance for use with the GPV, take into
consideration the various requirements and limitations in the venting
installation section for the following models:
Models equipped with an Intermittent Pilot Ignition (IPI)
It is recommended that the GPV be used with a gas appliance
equipped with an Intermittent Pilot Ignition (IPI). Downward vertical
vent runs are permitted with an IPI system. See venting section in
appropriate PVA installation instructions.
Models equipped with Millivolt / Standing Pilot
Downward vertical vent runs are not permitted with a standing
pilot system. See venting section in appropriate PVA installation
instructions.
INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER to
conform with local codes. In absence of local codes, install to the
current National Building Code of Canada or to regional building
codes in the United States. It must be electrically conneceted and
grounded in accordance with local codes. In the absence of local
codes, use the current CSA C22.1 Canadian Electrical Code in
Canada or the ANSI/NFPA 70 Electrical Code in the United States.
The GPV operates on 120 VAC 60 Hz electrical service which is
supplied at the firebox junction box.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
$10.00
appliance and PVA instructions.
ADD MANUAL TITLE
Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com
INSTALLATION
MANUAL
Gas Power Vent
CANADIAN AND AMERICAN NATIONAL STANDARDS:
FOR VENTED DECORATIVE GAS APPLIANCES
FOR VENTED GAS FIREPLACE HEATERS
ENGLISH
FRENCH PG. 29
(GPV)
CERTIFIED TO:
CSA 2.22 AND ANSI Z21.50
CSA 2.33 AND ANSI Z21.88
C E R T I F I E D
US
CAN
W415-1160 / E / 03.11.22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GPV and is the answer not in the manual?

Questions and answers

Summary of Contents for Wolf Steel GPV

  • Page 1 FOR VENTED GAS FIREPLACE HEATERS C E R T I F I E D Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com $10.00...
  • Page 2: Table Of Contents

    table of contents venting installation overview vent terminal clearances vent lengths power vent terminal 1.4.1 terminal installation firestop venting installation adding vent length 1.6.1 power vent installation 1.6.2 initial firing procedures 1.6.3 electrical connection 1.6.4 hard wiring connection 1.6.5 receptacle wiring diagram 1.6.6 electrical box installation restrictor plate installation wiring diagram and installation...
  • Page 3: Installation Overview

    installation overview W415-1160 / E / 03.11.22...
  • Page 4: Vent Terminal Clearances

    vent terminal clearances COVERED BALCONY APPLICATIONS ††* Covered balcony applications ††* = 3 feet ≤ 15 feet = 2 x ≤ 15 feet = 3 feet ACTUAL = 2 x (0.9m) (4.6m) ACTUAL (0.9m) (4.6m) note: INSTALLATIONS note: Wall terminals are for illustration purposes only. Size and shapes may vary. Wall terminal INSTALLATIONS CANADA U.S.A.
  • Page 5: Vent Lengths

    Insert the wiring through the electrical access plate and engage the conduit bushing. Re-secure this plate. NOTE: The GPV includes a 20 foot (6.1m) 10 1/4” wire harness cable. If this cable does not reach the appliance, (260.4mm)
  • Page 6: Firestop Venting Installation

    Mill Pac (not supplied) must be used on the joint connecting the inner fl ex pipe and the exhaust fl ue collar. Use only approved fl exible vent pipe kits marked: “Wolf Steel Approved Venting” or “E2” as identifi ed by the stamp only on the fl ex pipes. 17.1 adding vent length...
  • Page 7: Power Vent Installation

    1.6.1 power vent installation Stretch the inner fl ex pipe to the required length taking into Caulking account the additional length needed for the fi nished wall surface. Slip the vent pipe a minimum of 3” (76.2mm) over the inner sleeve of the terminal and secure with a minimum of three #8 screws.
  • Page 8: Initial Firing Procedures

    1.6.2 initial firing procedures WARNING • Always light the pilot whether for the first time or if the gas supply has run out with the glass door opened or removed. Purge should be performed by a qualified service technician. Assure that a continuous gas flow is at the burner before closing the door.
  • Page 9: Electrical Box Installation

    1” (25.4mm) from all venting. NOTE: The GPV includes a 20 foot (6.1m) wire harness. If this harness does not reach the appliance, then it may be cut and a splice added. These connections must conform with local codes or, in the absence of local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/...
  • Page 10: Sit Ipi Proflame 0 880/886 For Single Pole Switch Or Optional Remote Control

    1.8.1 SIT IPI Proflame 0 880/886 for single pole switch or optional remote control GREEN ORANGE VALVE VALVE ELECTRONIC PF0 BOARD USB POWER WHITE PACK BLACK BLUE ON / OFF CPI / IPI SWITCH (OPTIONAL) YELLOW YELLOW Single pole switch W415-1160 / E / 03.11.22...
  • Page 11: Sit Ipi 885 Proflame 1 Equipped With A Remote Control

    1.8.2 SIT IPI 885 Proflame 1 equipped with a remote control Disconnect the wires labeled ON/OFF (White/Green) and TH (Green). Reconnect them to the corresponding male/female connectors on the Power vent control module. Disconnect the two D/C (Red/Black) wires from each other and reconnect them to the corresponding D/C connectors on the Power vent control module.
  • Page 12: Sit Ipi 885 Proflame 1 Not Equipped With A Remote Control

    1.8.3 SIT IPI 885 Proflame 1 not equipped with a remote control Disconnect the wires labeled ON/OFF (Green) from the switch wire (Brown). Reconnect them to the corresponding male/female connectors on the Power vent control module. Disconnect the two D/C (Red/Black) wires from each other and reconnect them to the corresponding D/C connectors on the Power vent control module.
  • Page 13: Sit Ipi Proflame 2 Control System

    Connect the other (yellow) wire from the PVCM to the valve. Connect the wire harness from the GPV terminal to the harness from the PVCM. Disconnect the MAIN ON/OFF (JUMPER) from "X4" and discard. Connect the (orange) wire from the PVCM to the "X4"...
  • Page 14: Sit Ipi Proflame 2 Control System (For Use With Pvalx3 / Pvalx5)

    1.8.5 SIT IPI Proflame 2 control system (for use with PVALX3 / PVALX5) Control Board Installation 1. Identify all wires to avoid confusion when reinstalling the control board. Disconnect all wires from control board. note: Wire connections will only fit in designated locations. 2.
  • Page 15 RESET BUTTON BATTERY HOLDER COMPLETE WITH PROGRAM BUTTON 5. Connect the other end to the wire harness provided with the GPV. 6. Test your appliance by turning it on using the remote. note: There is a 15 second pre-purge before the burner will light and a 120 second post-purge once the appli- ance is turned off before the blower stops.
  • Page 16: Sit Millivolt 820

    BLOWER YELLOW YELLOW Power Vent VAC SWITCH Control Module YELLOW YELLOW GREEN GPV Terminal Double Pole Appliance Switch Junction Box IMPORTANT: A RECEPTACLE MAY NEED TO BE INSTALLED AS A POWER SOURCE FOR THE GPV. W415-1160 / E / 03.11.22...
  • Page 17: Sit Ipi Proflame 2 For Single Pole Switch

    YELLOW Power Vent VAC SWITCH Control Module YELLOW YELLOW GREEN GPV Terminal Switch/Thermostat (Not Supplied) Appliance Junction Box Remote Receiver (Not Supplied) Connect the two yellow wires from the PVCM to the wires coming off the 'X4' MAIN ON/OFF (jumper).
  • Page 18: Sit Millivolt 820 Nova And Equipped With Optional Remote Control

    VAC SWITCH Control Module YELLOW YELLOW GREEN GPV Terminal Double Pole Appliance Switch Junction Box Disconnect one of the two wires from the receiver to the valve. Connect it to one of the yellow wires from the power vent control module.
  • Page 19: Sit Ipi 880/886 Proflame

    Connect the jumper wires to the wire labeled ON/OFF (Green/White) and the wire labelled TH (Green). Connect the other end of the jumper wires to the Yellow wires from the Power vent control module. DC BACK-UP GREEN (NOT ALLOWED ORANGE WITH GPV ACS/IPI INSTALLATION) SWITCH (OPTIONAL) TRANSFORMER...
  • Page 20: 10Sit Ipi 880/886 For Single Pole Switch Or Optional Remote Control

    Connect the jumper wires to the wire labeled ON/OFF (Green/White) and the wire labelled TH (Green). Connect the other end of the jumper wires to the Yellow wires from the Power vent control module. DC BACK-UP GREEN (NOT ALLOWED ORANGE WITH GPV ACS/IPI INSTALLATION) SWITCH (OPTIONAL) TRANSFORMER...
  • Page 21: 11Dexen Ipi 6003-3V

    YELLOW Relay BLOWER Power VAC SWITCH Vent Control YELLOW Module YELLOW GREEN GPV Terminal Double Pole Switch Appliance Junction Box IMPORTANT: A receptacle may need to be installed as a power source for the GPV. W415-1160 / E / 03.11.22...
  • Page 22: 12Dexen Ipi 6003-3V Requiring A Single Pole Switch Or Optional Remote Control

    ORANGE BLACK YELLOW GREEN Dexen Gas Valve BROWN YELLOW Battery BROWN YELLOW Relay BLOWER Power VAC SWITCH Vent Control YELLOW Module YELLOW GREEN GPV Terminal Switch/Thermostat (Not Supplied) Remote Receiver (Not Supplied) Appliance Junction Box W415-1160 / E / 03.11.22...
  • Page 23: 13Dexen H3V Requiring A Single Pole Switch Or Optional Remote Control

    YELLOW ELAY BROWN YELLOW BLOWER Power VAC SWITCH Vent Control YELLOW Module YELLOW GREEN GPV Terminal VUE DE DESSUS Switch/Thermostat (Not Supplied) Remote Receiver (Not Supplied) VUE DE CÔTÉ Appliance Junction Box SORTIE DE PILOTE W415-1160 / E / 03.11.22...
  • Page 24: Adjustments

    2.0 adjustments venturi adjustments This appliance has an air shutter that has been factory set open according to the chart below: VENTURI Regardless of venturi orientation, closing the air shutter will cause a more BURNER yellow flame, but can lead to carbonization. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports.
  • Page 25: Replacements

    3.0 replacements WARNING • Failure to position the parts in accordance with this manual or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury. Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts can be ordered through your Authorized dealer / distributor.
  • Page 26: Troubleshooting

    4.0 troubleshooting WARNING • Always light the pilot whether for the first time or if the gas supply has run out, with the glass door open or removed. • In some instances the system may not light pilot/burner with the door open/removed. Partially blocking the exhaust flue collar will allow the safety pressure switch to activate and allow gas flow to the pilot during the initial test firing.
  • Page 27 29.1 W415-1160 / E / 03.11.22...
  • Page 28 WOLF STEEL LTD. 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 103 Miller Drive, Crittenden, Kentucky, USA 41030 7200 Trans Canada Highway, Montreal, Quebec, Canada H4T 1A3 Tel: 1-866-820-8686...
  • Page 29 POUR FOYER AU GAZ À ÉVACUATION C E R T I F I E D Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com $10.00...
  • Page 30: Évacuation

    table des matières évacuation vue d'ensemble d'installation dégagements de la terminaison à évacuation mécanique longueurs des conduits d'évents terminaison évacuation mécanique 1.4.1 installation de la terminaison installation de l'évacuation et de l'espaceur coupe-feu ajout de longueur d'évent 1.6.1 installation des conduits d'évent et de la terminaison 1.6.2 procédures pour la première utilisation 1.6.3 branchement électrique 1.6.4 branchement par câble...
  • Page 31: Vue D'ensemble D'installation

    vue d'ensemble d'installation W415-1160 / E / 03.11.22...
  • Page 32: Dégagements De La Terminaison À Évacuation Mécanique

    dégagements de la terminaison à évacuation mécanique APPLICATIONS POUR BALCON COUVERT ††* = 3 pieds ≤ 15 pieds = 2 x INSTALLATION RÉELLE (4,6m) (0,9m) CANADA É.-U. 12” 12” Dégagement au-dessus du sol, d’une véranda, d’une terrasse en bois ou d’un balcon. (304.8mm) (304.8mm) 12”...
  • Page 33: Longueurs Des Conduits D'évents

    B. Insérez le fi lage à travers la plaque d’accès électrique et engagez la bague (260.4mm) du conduit. Réinstallez la plaque. REMARQUE: La terminaison GPV 11 1/4” comprend un harnais de fi ls d’une longueur 20 pieds (6.1m). Si le (285.8mm)
  • Page 34: Installation De L'évacuation Et De L'espaceur Coupe-Feu

    à la buse de l’appareil qui doit être scellé avec le scellant Mill Pac. N’utilisez que les ensembles certifi és de gaines fl exibles portant l’inscription: « Wolf Steel Approved Venting » « E2 » comme identifi é par les gaines fl exible. ajout de longueur d'évent Bague d’accouple- ment intérieure...
  • Page 35: Installation Des Conduits D'évent Et De La Terminaison

    1.6.1 installation des conduits d'évent et de la terminaison Étirez la gaine fl exible intérieure à la longueur requise en tenant compte Calfeutrage de la longueur additionnelle nécessaire pour la surface du mur fi ni. Glissez la gaine fl exible sur le manchon intérieur de la terminaison en assurant un chevauchement minimal de 3”...
  • Page 36: Branchement Électrique

    1.6.3 branchement électrique AVERTISSEMENT • N’utilisez pas cet appareil si une partie quelconque a été submergée. Contactez immédiatement un technicien de service qualifi é pour inspecter l’appareil pour des dommages au circuit électrique. • Risque de chocs électriques ou d’explosion. Ne branchez pas le 110 V à la soupape ou à l’interrupteur mural de l’appareil.
  • Page 37: Installation Du Boîtier Électrique

    à au moins 1” (25,4m) de toute évacuation. NOTE: La terminaison GPV comprend un harnais de fil de 20 pieds (6,1m). Si ce harnais n’est pas as- sez long pour atteindre l’appareil, vous pouvez le couper et ajouter une jonction de fil. Ces connexions doivent être conformes aux codes locaux.
  • Page 38: Soupape Sit Ipi Pf0 880/886 Avec Un Interrupteur Unipolaire Ou Télécommande

    1.8.1 soupape SIT IPI PF0 880/886 avec un interrupteur unipolaire ou télécommande VERT ORANGE INTERRUPTEUR ACS/IPI (OPTIONNEL) SOUPAPE VALVE ÉLECTRONIQUE IPI / CPI PANNEAU IPI ANNEAU DE MISE À LA TERRE MISE À LA TERRE USB POWER PACK (NOT SUPPLIED) JAUNE JAUNE Interrupteur unipolaire...
  • Page 39: Sit Ipi 885 Proflame 1 Équipé Avec Une Télécommande

    1.8.2 SIT IPI 885 Proflame 1 équipé avec une télécommande Débranchez les fils identifiés MARCHE/ARRÊT (blanc/vert) et TH (vert). Rebranchez-les aux connecteurs mâle/femelle sur le module de contrôle de la terminaison. Débranchez les 2 fils CC (rouge/noir) l'un de l'autre et rebranchez-les aux connecteurs CC correspondants sur le module de contrôle de la terminaison.
  • Page 40: Sit Ipi 885 Proflame 1 Non Équipé Avec Une Télécommande

    1.8.3 SIT IPI 885 Proflame 1 non équipé avec une télécommande Débranchez les fils identifiés MARCHE/ARRÊT (vert) du fil de l'interrupteur (brun). Rebranchez-les aux connecteurs mâle/femelle sur le module de contrôle de la terminaison. Débranchez les 2 fils CC (rouge/noir) l'un de l'autre et rebranchez-les aux connecteurs CC correspondants sur le module de contrôle de la terminaison.
  • Page 41: Sit Ipi Proflame 2 Système De Contrôle

    Branchez l'autre fil (jaune) du module de contrôle de la terminaison à la soupape. Branchez le harnais de fils de la terminaison à évacuation mécanique GPV au harnais de fils du module de contrôle de la terminaison.
  • Page 42: Sit Ipi Proflame 2 Système De Contrôle (Pour Utilisation Avec Pvalx3 / Pvalx5)

    1.8.5 SIT IPI Proflame 2 système de contrôle (pour utilisation avec PVALX3 / PVALX5) Installation du Panneau de Contrôle 1. Identifié toutes les fils pour prévenir confusion lorsque le panneau de contrôle doit être réinstallé. Débranchez toutes les fils du panneau de contrôle. note: Connexions des câbles ne rentrera pas dans des endroits désignés.
  • Page 43 CAS DE PILES FOURNI AVEC BOUTON WITH PROGRAM BUTTON DE PROGRAMME 5. Branchez l’autre côté au harnais de fils fourni avec le GPV. 6. Testez votre appareil en le tournant par utilisation du télécommande. note: Il y a une deuxième purge de 15 secondes préalable avant que le brûleur s’allume et une purge après 120 seconds quand l’appareil est éteint avant l’arrêt de la soufflerie.
  • Page 44: Soupape Millivolt Sit 820

    INTERRUPTEUR contrôle DE PRESSION de la terminaison JAUNE JAUNE VERT Terminaison GPV Interrupteur Boîte de bipolaire dérivation de l’appareil IMPORTANT: Un réceptacle devra possiblement être installé comme source d'alimentation pour la ter- minaison à évacuation mécanique. W415-1160 / E / 03.11.22...
  • Page 45: Sit Ipi Proflame 2 Avec Un Interrupteur Unipolaire

    INTERRUPTEUR contrôle DE PRESSION de la terminaison JAUNE JAUNE VERT Terminaison GPV Interrupteur bipolaire Boîte de Récepteur dérivation de (Non fourni) l’appareil Branchez les deux fils jaune du module de contrôle de la terminaison aux fils de dérivation reliés à « X4 »...
  • Page 46: Soupape Millivolt Sit 820 Nova Fourni Avec Une Télécommande Optionnel

    DE PRESSION contrôle de la JAUNE terminaison JAUNE VERT Terminaison GPV Interrupteur Boîte de bipolaire dérivation de l’appareil Débranchez un des deux fils du récepteur reliés à la soupape, puis branchez-le à un des fils jaunes du module de contrôle de la terminaison.
  • Page 47: Sit Ipi 880/886 Proflame

    Branchez l'autre bout des fils de dérivation aux fils jaunes du module de contrôle de la terminaison. ALIMENTATION DE SECOURS CC VERT (INTERDIT AVEC ORANGE L’INSTALLATION INTERRUPTEUR DU GPV) ACS/IPI (OPTIONNEL) TRANSFORMATEUR SOUPAPE VALVE ÉLECTRONIQUE IPI / CPI PANNEAU IPI...
  • Page 48: 10Soupape Sit Ipi 880/886 Avec Un Interrupteur Unipolaire Ou Télécommande Optionnel

    Branchez l'autre extrémité des fils de dérivation aux fils jaunes du module de contrôle de la terminaison. ALIMENTATION DE SECOURS CC VERT (INTERDIT AVEC ORANGE L’INSTALLATION INTERRUPTEUR DU GPV) ACS/IPI (OPTIONNEL) TRANSFORMATEUR SOUPAPE VALVE ÉLECTRONIQUE IPI / CPI PANNEAU IPI...
  • Page 49: 11Soupape Dexen Ipi 6003-3V

    Module de INTERRUPTEUR contrôle DE PRESSION de la terminaison JAUNE JAUNE Terminaison GPV VERT Interrupteur Boîte de dérivation Bipolaire de l’appareil IMPORTANT: Un réceptacle devra possiblement être installé comme source W415-1160 / E / 03.11.22 d'alimentation pour la terminaison à évacuation mécanique.
  • Page 50 Soupape de gaz Dexen BRUN JAUNE BRUN JAUNE Relais de batterie SOUFFLERIE Module de INTERRUPTEUR contrôle DE PRESSION de la terminaison JAUNE JAUNE Terminaison GPV Interrupteur Thermostat/Interrupteur (non fourni) Boîte de dérivation de l’appareil Récepteur (non fourni) W415-1160 / E / 03.11.22...
  • Page 51: 13Soupape Dexen H3V Nécessitant Un Interrupteur Unipolaire Ou Télécommande Optionnel

    BRUN JAUNE SOUFFLERIE INTERRUPTEUR Module de DE PRESSION contrôle de la JAUNE terminaison JAUNE VERT Terminaison GPV VUE DE DESSUS Thermostat/Interrupteur (non fourni) Récepteur VUE DE (non fourni) CÔTÉ Boîte de dérivation SORTIE DE PILOTE de l’appareil W415-1160 / E / 03.11.22...
  • Page 52: Réglages

    2.0 réglages réglage du venturi L’ouverture du volet d’air a été préréglée en usine selon le tableau ci-dessous: Indépendamment de l’orientation du venturi, plus le volet est fermé, plus la VENTURI flamme est jaune et aura tendance à causer des dépôts de carbone. Plus le volet est ouvert, plus la flamme est bleue et plus elle a tendance à...
  • Page 53: Rechanges

    3.0 rechanges AVERTISSEMENT • Omettre de positionner les pièces conformément à ce manuel ou d’utiliser uniquement des pièces spécifi quement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles. Contactez votre détaillant pour les questions concernant les prix et la disponibilité des pièces de remplace- ment.
  • Page 54: Guide De Dépannage

    4.0 guide de dépannage AVERTISSEMENT • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l'approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Dans certains cas, le système n'allumera pas la veilleuse si la porte est ouverte/retirée. En bloquant partiellement la buse, l'interrupteur de pression s'activera et permettra un apport de gaz à...
  • Page 55 29.1 W415-1160 / E / 03.11.22...
  • Page 56 WOLF STEEL LTD. 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 103 Miller Drive, Crittenden, Kentucky, USA 41030 7200 Trans Canada Highway, Montreal, Quebec, Canada H4T 1A3 Tel: 1-866-820-8686...

Table of Contents