7. The conversion data label must be fi lled out and attached adjacent to the valve.
8. Position the burner assembly in place inside the fi rebox but do not secure. Lift the burner assembly up then manually
engage the larger end of the rod over the left side of the shutter. Ensure the rubber grommet is correctly positioned around
the air shutter stud (Fig. 5). Once fully engaged, secure the burner assembly. Ensure the orifi ce is engaged.
9. Never place excessive media on the burner as this can result in carboning or an unappealing fl ame
characteristic. Never place media in the pilot housing or over the pilot. Always check that the appliance ignites
smoothly across the entire burner to ensure media does not compromise performance. Pay particular attention when using
power vents to ensure media placement does not affect ignition or fl ame characteristics. Adjust the air shutter according to
the table under "venturi adjustment".
note:
Media should be installed evenly across the burner tray and a moderate amount of
media placed on the burner itself and, if necessary, adjusted to achieve a pleasing fl ame
appearance.
10. Turn on the electrical supply to the appliance. Turn on the gas supply. Then light the
pilot to ensure the gas lines have been purged.
11. Check for gas leaks by brushing on a soap and water solution. Refer to the lighting
instructions in your installation manual. Do not use open fl ame. Once all systems
have been checked, reinstall media.
12. Install indicator label (supplied) onto the end of air shutter adjustment rod (Fig. 5).
13. Reinstall the glass door, trim, and glass guard assembly or safety barrier.
Purge all gas lines with the glass door off. Assure that a continuous fl ow is at the burner before replacing the glass
door and glass guard assembly or safety barrier.
NOTE: Your appliance may be equipped with either a rotating or a sliding air shutter cap.
EXTERNALLY ADJUSTABLE AIR SHUTTER
This appliance is equipped with an externally adjustable air shutter that is not preset from factory. Any adjustment will be required
after any change to the appliance. Any adjustments made to the shutter must be done with the burner and all media installed into
the unit. It is important to operate the unit and verify that the air shutter is opened to the correct amount to prevent either fl ame
lifting or carbonization. To open and close the shutter, pull the knob away from the unit and push the knob towards the appliance
respectively.
Small adjustments on the shutter can have a drastic effect on the fl ame appearance; it is recommended to adjust the shutter in
1/8" increments.
AIR SHUTTER ADJUSTMENT
Appliance
TLV50
TLV62
TLV74
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada •
ADJUSTMENTS

VENTURI ADJUSTMENT

Air Shutter
1/2" (13mm)
1/2" (13mm)
1/2" (13mm)
MAXIMUM INPUT RATINGS
Appliance
Propane
TLV50
31,500 BTU/hr
38,000 BTU/hr
TLV62
TLV74
41,500 BTU/hr