Introduction

The Meter is a handheld and battery operated very convenient small Tool, that is specially used to measuring SMD(Surface Mounting Device),there are resistor, Capacitor, Diode, Zener and LED, Moreover, the Meter have the continuity checking function And battery power Measurement.

The Meter is designed to meet IEC1010-1 standard and Stipulation of 2-Pollution Grade.

The Meter conform to the European Union"s following Requirement: CE regulation 89/336 (EMC Electromagnetic Compatibility).

The entire outer surface of the Meter case has been with thermo plastic elastomer, and the two testing pins has been gold-plated, so that it is reduce pin contact resistance and prevent to get rusty.

This operating instruction covers information on safety and caution, so please read relevant information carefully and observe all the warming and note strictly.

Safety Note

The following safety notes should be observed prior to using this Meter and any associated accessory. Although the Meter do not used to measuring to exceed Safety Voltage, but there are situations where hazardous condition -on may be present.

  • Inspect the Meter case before using. Do Not use damaged device.
  • Inspect the Pin Holder and Pin gold -plated state.
  • Do not attempt use the Meter as tweezers to prevent the pin tip from damage.
  • Do not use in the environment with explosive gas, vapor, or dust.


Never use the Meter on alive circuits.

Explanation of Control and Indicators

Product Illustration

Product Illustration

  1. LCD
  2. "REL"Push Button
  3. "FUNC" Push Button Function Select
  4. FUNCTION Switch
  5. Pin Holder
  6. Test Pin (Gold plated, 'INPUT' Terminal)
  7. Test Pin (Gold plated, 'COM' Terminal)
  8. Battery cover

Push Buttons

  1. "FUNC":it is the function select key that acts trigger.
    Use the Push Button as switch of Resistance/Capacitance/Diode/Continuity when the FUNCTION Switch turn on "R/D/C" Range.
    The Meter is have not Power Key. When install the 1.5V(AAA)×2 Battery, The Meter immediately Power ON.
  2. "REL" Key: Press "REL" Button to Enter or exit the relative value measuring mode.
  3. Push the key, the present display value will be stored in memory, then the new display value is the difference between input value and stored data.

Note: after auto power-OFF is active, pushing the "REL" key can turn on the Meter again, and pushing the "FUNC" key can turn on again when the Meter on the "R/D/C" Range, But the meter can not auto power off, want to power off, must be break battery connenction.

LCD Display

LCD Display

NO Indicator Meaning
1 AUTO Auto Ranging
2 DC Direct current
3 REL Relative Testing
4 Diode Checking Mode
5 Continuity Checking Mode
6 nuF Capacitance Units(nF,uF)
7 MKΩ Resistance Units(Ω, KΩ,MΩ)
8 V Voltage Units
9 Low Battery lndicator

Specification

4-1.General Feature

  • 4000 count LCD display.
  • Auto ranges.
  • Over-rang indication display "OL"
  • Zener diode Test
  • LED Test
  • Battery Power Test
  • Specialized SMD TEST or TEST DIP Component with leade.
    SMD TEST or TEST DIP Component with leade
  • Low Battery Indication
  • Power Supply: 1.5V(AAA)×2 Battery
  • Operating temperature & Humidity: 0-40'C (32-104'F) &<80%RH
  • Storage temperature & Humidity:-10-50
  • Safety Class: IEC1010-1,CAT Ⅲ
  • Auto Power OFF:lf the Meter is idle for more than 15 minutes, the Meter automatically tums the power off.
  • EMC:According to CE regulation 89/336.
  • Dimension(L×W×H) & Weight: 206 X 36 X 25mm, Approx.50 g
  • Environmental condition:
    1. Indoor use;
    2. Altitude up to 2000meter.
  • Accessory:
    1. Spare Test Pin: 2PCS
    2. Special Test Leads: electric rating 500V 10A

Electrical Specification

Function. Range Resolution Accuracy
Resistance 400Ω/4KΩ/40K/400K/
4MΩ
40MΩ
0.1Ω ±(2.0%rdg+5dgt)
±(2.5rd%+5dgt)
Capacitance 4nF/40nF/ 400nF/4μF/ 40μF/200μF 1pF ±(2.5%rdg+5dgt) "
±(3%rdg+5dgt)
Diode Test Open Voltage: 1.5V, Testing Current: 2mA
Continuity Check When the resistance is less than approx.30Ω,The Buzzer is sounded.
Zener/LED Open Voltage: MIN 20V,
Testing Current: Appr. 1mA
BATTERY POWER Loading Current: Approx. 10mA ±(1.5rd%+5dgt)

Testing Operation


When measuring SMD device on the PCB, you must Disconnect power and discharge all high-voltage capacitors.

Resistance Measurement

  1. Set the FUNCTION Switch to "R/D/C"
  2. Connect the Test Pins to across the resistance under measurement.
  3. You can get reading from LCD.
  4. When test low value of the resistance, You can short two Test Pins, And Press "REL" Button to clear zero, then testing to obtain volue of the resisitance.

Capacitance Measurement

  1. Set the FUNCTION Switch at "R/D/C",
    And press 'FUNC' button until symbol of "" is displayed on LCD.
  2. Connect the Test Pins to across the Capacitance under measurement.
  3. You can get reading from LCD.
  4. When test low value of the capacitance, You can press "REL" Button to clear zero, then testing to obtain precist volue of the Capacitance.


To avoid damage to the Meter or to the equipment under test, disconnect power and discharge all high-voltage capacitors before measurement capacitance.
When testing large capacitance, it will take longer time before the final indication(For 100uF, it will take about 15 seconds).

Diode Check

  1. Set the FUNCTION Switch to "R/D/C",
    And press „FUNC" button until symbol of "" is displayed on LCD.
  2. Connect 'INPUT' Test Pin to the anode, and Connect 'COM' Test Pin to the cathode of the diode under testing.
  3. You can get reading from LCD. A good silicon junction drop between 0.5V-0.8V.

Continuity Check

  1. Set the FUNCTION Switch at "R/D/C", And press „FUNC" button until symbol of " " is displayed on LCD.
  2. Connect test pins across two points of the circuit under testing.
    When the resistance reading is less than 10~60 Ω, the buzzer generates 2KHz beep to indicate continuity.

Zener or LED Check

  1. Set the FUNCTION Switch to " "
  2. Connect 'INPUT' Test Pin to the anode, and Connect 'COM' Test Pin to the cathode of the ZENER/LED under testing.
  3. The measured value of Zener Voltage show on the LCD, Or show LED working Voltage on the LCD.

Battery Power Measure

  1. Set the FUNCTION Switch to " "
  2. Connect 'INPUT' Test Pin to the anode, and Connect 'COM' Test Pin to the cathode of the Battery under testing.
  3. The measured value of Battery Voltage at DC10mA load show on the LCD,.

Maintenance

Replacing The Battery

When meter display ,the battery must be replaced to maintain normal operaion.

  1. Open the battery cover on the bottom case by pushing the battery cover.
  2. Remove old battery and put new two into battery holder.

Note:
Battery type: 1.5V(AAA)×2 If you do not use the meter a long time, please Remove the batteries from the meter.

Cleaning

The meter can be cleaned with soft clean cloth to remove any oil, grease or grim. Do not use liquid solvent or detergent.
Above picture and content just for your reference. Please be subject to the actual products if anything different or updated.
Please pardon for not informing in advance.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download HoldPeak 990B, 990C - SMD Meter Manual

Advertisement

Need help?

Need help?

Do you have a question about the 990B and is the answer not in the manual?

Questions and answers

Table of Contents