HOLDPEAK 870H
OPERATION MANUAL
This LCD Auto Range & Auto Power off Digital AC/DC WATT
clamp multimeter is a portable, 3 3/4-digit multimeter. It is ideally
suited for field, laboratory, shop and home applications.
1. SAFETY INFORMATION
The following safety information must be observed to insure
maximum personal safety during the operation at this meter.
1) When measuring voltage ensure that instrument is not
switched to the current range, resistance range, diode and
continuity range, capacitance range or temperature range.
2) Use extreme care when measuring voltage above 50V.
especially from sources where high energy is existed.
3) Avoid making connections to "live" circuits whenever possible.
4) Before making resistance measurements, diode or continuity
test, capacitance test or temperature test, ensure that the
circuit under test is de-energized.
5) Always ensure that the correct function and range is selected.
6) Extreme care should be taken when using the instrument to
conjunction with a current transformer connected to the
terminals if an open circuit occurs.
7) Ensure that the test leads and probes are in good condition
with no damage to the insulation.
8) Take care not to exceed the over-load limits as given in the
specifications.
9) Before opening the cover of the battery cabinet to replace
batteries. disconnect the test leads from any external circuit,
set the selector switch to "OFF" position.
10) Keep the fingers after the protection ring when measuring
through the instrument lead.
1) Change the battery when the symbol "
1
incorrect data.
2. Panel Layout
1)
Rotary Switch: use this switch to select functions and ranges.
2) D.HOLD/ Back Light key:In any range, push the key, the
present display value will be locked and the " H " symbol will
appear, push it again to exit HOLD and the " H"symbol
disappear. Press "D.HOLD" button more than 2 seconds, the
back light will light, press it more than 2 seconds again, the
back light will light off.
3) SELECT key:This key work on the "CAP
the key to choose resistance, diode ,continuity or capacitance
test. And on the voltag or current range,change to DC/AC.
4)
RANGE key:Push the key to select manual mode, push it
again to change the range, press the key for more than 2
seconds to go back auto range mode. But in Hz/Duty and
Capacitance measurement, it can not select manual range
mode.
5) Hz/DUTY key:In "
V
push the key, you can measure the Hz ,push again, can
measure the duty.
6) REL key: Push the key, the present display value will be stored
in memory, then the new display value is the difference
between input value and stored data. In Hz/Duty measurement,
it can not work.
7) LCD Display:LCD Dual Display, facilitates reads the data.
8)T+V Ω Input Jack 、COM Input Jack、T- Input Jack
2. SPECIFICATIONS
2.1 GENERAL SPECIFICATIONS
Display: 3 3/4 digit LCD with a max. reading of 3999.
Range control: Auto range control.
Polarity: Automatic negative polarity indication.
" appears to avoid
4 0k W
4 0 0 k W
C o sa
Temp
SE L E C T R A N G E H z/D uty
RE L
U
T-
Ω" range , Push
4 0 0 A /1 0 0 0 A
" or "
/H z
Zero adjustment: Automalic.
Overrange indication: Only the "OL" display.
Low battery: The " " is display when the battery voltage is below 6.2V.
Auto Power Off: 30 minutes after stopping the switch or no push
button, the meter automatically enter to power off
mode.Push button or run switch, auto power off disable.
Safety Standards: The meter is up to the standards of IEC1010
Double Insulation, Pollution Degree 2, Overvoltage
Category Ⅱ. Clamp opening size: 45mm.
Operating Environment: Temperature 32~104°F(0~40℃),
humidity<80%RH.
Storage Environment: Temperature -4~140°F(-20~60℃),
humidity<90%RH.
Power supply: 9V Zinc-carbon battery.
Dimension: 225(H)×97(W)×40(D)mm.
Weight: Approx. 350g (including batteries).
2.2 ELECTRICAL SPECIFICATIONS
Accuracies are ±(% of reading +numder in last digit) at 23±5℃,
≤70%RH.
2.2.1 DC Voltage
Range
400mV
4V
40V
400V
1000V
Overload protection: 1000V DC/750Vrms AC
Impedance: 10MΩ,More than 100MΩ on 400mV scale
2.2.2 AC Voltage
Range
400mV
3.0% of rdg+15 digits
4V
40V
400V
750V
Average sensing, calibrated to rms of sine wave
Overload protection: 1000V DC/750Vrms AC
Impedance: 10MΩ.
2.2.3 DC Current
Range
400A
0~800
1000A
800~1000
Overload protection: 1000Arms within 60 seconds
2.2.4 AC Current
Range
400A
1000A
Average sensing, calibrated to rms of sine wave
Overload protection: 1000Arms within 60 seconds
2.2.5 Resistance
Range
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
Overload protection: 250V DC/250Vrms AC
2.2.6 Capacitance
Range
51.2nF
512nF
5.12μF
51.2μF
" range,
100μF
Overload protection: 250V DC/250Vrms AC
2.2.7 Frequency AND Duty cycle
Range
5.12Hz
51.2Hz
512Hz
5.12kHz
51.2kHz
100kHz
Duty cycle: 0.1%~99.9% Accuracy:
Accuracy
1.0% of rdg+5digits
1.5% of rdg+5 digits
Accuracy
Resolution
0.1mV
1.5% of rdg+5 digits
100mV
2.5% of rdg+5 digits
Accuracy
3.0% of rdg+10 digits
3.5% of rdg+10 digits
6.5% of rdg+10 digits
Accuracy
3.0% of rdg+10 digits
3.5% of rdg+10 digits
Accuracy
1.8% of rdg+15 digits
1.2% of rdg+15 digits
2.5% of rdg+15 digits
Accuracy
3.5% of rdg+25 digits
2.5% of rdg+25 digits
5.0% of rdg+20 digits
Accuracy
Resolution
0.01Hz
0.1Hz
1Hz
0.5% of rdg+15 digits
10Hz
100Hz
1kHz
Resolution
0.1mV
1mV
10mV
100mV
1V
Frequency
50~100Hz
1mV
10mV
50~400Hz
1V
50~100Hz
Resolution
0.1A
1A
Resolution Frequency
0.1A
50~60Hz
1A
Resolution
0.1Ω
10Ω
100Ω
1kΩ
10kΩ
Resolution
10PF
100PF
1nF
10nF
100nF
Sensitivity
Range of input
voltage:0.1V~7
50V AC
Range of input
voltage:6V~75
0V AC
±0.5

Advertisement

loading
Need help?

Need help?

Do you have a question about the 870H and is the answer not in the manual?

Questions and answers

Summary of Contents for HoldPeak 870H

  • Page 1 HOLDPEAK 870H Zero adjustment: Automalic. Overrange indication: Only the "OL" display. Low battery: The " " is display when the battery voltage is below 6.2V. OPERATION MANUAL Auto Power Off: 30 minutes after stopping the switch or no push button, the meter automatically enter to power off mode.Push button or run switch, auto power off disable.
  • Page 2 4) Open the clamp by pressing the jaw-opening handle and Overload protection: 250V DC/250Vrms AC clamp the live wire of the load by test, Let the live wire through 2.2.8 AC/DC Watt and Cosα test The clamp from surface of the meter, The meter will display Range Accuracy Resolution...