Error Codes - Venturo INST-32000 Owner's Manual

Logic controls
Table of Contents

Advertisement

TROUBLESHOOTING; ERROR CODES
VLC-K SYSTEM, OWNER'S MANUAL
ERROR CODES INDICATED BY FLASHING RED LED ON RECEIVER MODULE.
ERROR CODES ALSO VIEWABLE ON HISTOGRAM PAGE ON GATE.
EC
ERROR CODE EXPLANATION
1
RF COMMUNICATION PROBLEM
LOW INPUT VOLTAGE (<11V)
2
3
-
4
PRESSURE 1 ERROR
5
PRESSURE 2 ERROR
6
OVERLOAD ERROR
7
A2B ERROR
8
BOOM UP LIMIT ERROR
9
BOOM SENSOR ERROR
10
-
11 PROP. OUTPUT ERROR
12 BOOM UP OUTPUT ERROR
13 BOOM DOWN OUTPUT ERROR
14 BOOM OUT OUTPUT ERROR
15
BOOM IN OUTPUT ERROR
16 ROTATE CW OUTPUT ERROR
17 ROTATE CCW OUTPUT ERROR
18
WINCH UP OUTPUT ERROR
19
WINCH DOWN OUTPUT ERROR
20 ENGINE START OUTPUT ERROR
21 ENGINE STOP OUTPUT ERROR
22 HORN OUTPUT ERROR
23 LIGHT OUTPUT ERROR
24
AUX OUTPUT ERROR
25 GREEN LIGHT OUTPUT ERROR
26
AMBER LIGHT OUTPUT ERROR
27 RED LIGHT OUTPUT ERROR
28
TRIGGER INPUT ERROR
29
TRIGGER BEFORE SWITCH ERROR TRIGGER PULLED ON TX BEFORE SWITCH WAS ACTIVE
VLC-K ERROR CODES
TRANSMITTER IS OFF
TRANSMITTER WENT TO SLEEP MODE
INTERFERENCE IN RF COMMUNICATION LINK
SYSTEM VOLTAGE IS BELOW 11V (12V SYSTEM)
-
NO CURRENT OR TOO MUCH CURRENT (>20mA) READ AT
PRESSURE TRANSDUCER
OVERLOAD CONDITION PRESENT
ANTI-TWO BLOCK CONDITION PRESENT, A2B INPUT LOW
BOOM UP LIMIT ACTIVE, BOOM LIMIT INPUT LOW
NO CAN MESSAGES BEING RECEIVED FROM BOOM SENSOR
-
SHORT OR OPEN LOAD/COIL ON OUTPUT
NO VOLTAGE PRESENT ON TRIGGER IN TX
VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
POSSIBLE CAUSES
TITLE

ERROR CODES

VLC-K SYSTEM
DATE
SECTION
-
12-08-22
SUPERSEDES
32005
-

Advertisement

Table of Contents
loading

Table of Contents