Craftsman 919.16558 Owner's Manual page 17

Permanently lubricated single stage portable
Table of Contents

Advertisement

Available languages

Available languages

condense in the air tank. If not
drained, water will corrode and
weaken the air tank causing a risk
of air tank rupture.
6.
After the water has been drained,
close the drain valve (clockwise).
The air compressor can now be
stored.
NOTE: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, the
reinstalled.
Air Filter Inspection and
Replacement
and cylinder sleeve are very hot.
Do not touch. Allow compressor to
cool prior to servicing.
A dirty air filter will not allow the
compressor to operate at full
capacity. Keep the air filter clean at
all times.
1.
Remove the air filter and make
sure it is clean.
IMPORTANT: Do not operate the
compressor with the air filter
removed.
Risk of Bursting.
Water will
Risk of Burns.
Compressor head
Air Filter
2.
If dirty, rinse air filter with warm
water and squeeze dry.
3.
Replace air filter.
4.
Replace filter cover.
NOTE: If the air filter is extremely
dirty it will need to be replaced. Refer
to the "Repair Parts" for the correct
part number.
Air Compressor Pump Intake
and Exhaust Valves
Once a year have a Trained Service
Technician check the air compressor
pump intake and exhaust valves.
17- ENG