Remove the mounting plate (F) by rotating the
•
device and the mounting plate into opposite
directions (see figure 2+3).
•
Position the mounting plate on the desired site
and mark two bore holes (G) with a pen to the
wall or ceiling (see figure 4).
•
Use an appropriate drill to make the holes as
illustrated.
•
Use the screws and plugs supplied to fasten the
alarm siren.
5.2
Mounting on flush-mounted boxes
You can mount the alarm siren on flush-mounting/instal-
lation boxes using the holes (H) (see figure 4).
If the device is mounted to a flush-mounting box,
there may be no open conductor ends.
If changes or works have to be made on the
house installation (e.g. extension, bypass of
switch- or socket inserts) or the low-voltage
distribution for mounting or installing the device,
the
considered:
Please note!
Only to be installed by persons with the relevant
electro-technical knowledge and experience!*
following
safety
instruction
Mounting
must
be
31