Operation During A Power Outage - Heatilator RAVE42-IFT-B Owner's Manual

Hide thumbs Also See for RAVE42-IFT-B:
Table of Contents

Advertisement

J. Operation During A Power Outage
The IntelliFire Touch
intermittent pilot ignition system
®
comes with a battery backup system that enables the
system to operate in a power outage. The system offers
seamless transition from household AC power to battery
backup. A factory-installed battery pack is located in the
control cavity of the appliance. See Figure 3.6. Battery
longevity and performance will be affected by long term
exposure to the service temperatures of this appliance.
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Batteries tend to corrode over time.
Note: The battery backup system is disabled if a
Power Vent option option has been installed
for use with this appliance.
To Operate Fireplace Using Battery Power (DC):
1. The battery pack is located in the control cavity of
the appliance. To access the control cavity of the
appliance Remove the decorative barrier front and
glass assembly. See Section 4 for instructions on
glass assembly removal. See Figure 3.6 for location
of battery pack.
2. Locate the battery pack and remove it from the control
cavity. It is held in place by hook and loop fastener.
Insert four AA cell batteries. Battery polarity must be
correct or module damage will occur. See Figure 3.6.
A complete wiring diagram is included in the Electrical
section of the appliance Installation Manual.
3. Turn the appliance on according to the instructions
below for the appropriate type of control:
Standard Wall Switch or Factory-Installed ON/OFF
Switch:
Toggle the switch as you would under normal
circumstances.
Wireless Remote:
Remote receiver is integrated into the ignition module.
Use the remote to turn the appliance on.
To preserve battery life, do not use the HI/LO flame or
THERMOSTAT options.
Ignition Module:
Locate the ignition module in the control cavity.
Slide the ON/REMOTE/OFF switch to the ON position.
NOTICE: Some functionality will be lost when using battery
backup including fan, lights, or any other auxiliary functions
that require household 110-120 VAC power.
Heatilator • RAVE32-IFT-B, RAVE36-IFT-B, RAVE42-IFT-B Owner Manual • 2619-984 Rev. N • 11/22
To Return to Operation Using Electrical (AC) Power
Standard Wall Switch or Factory-Installed ON/OFF
Switch:
• Toggle the switch to OFF and remove the batteries
from the battery tray.
barrier front on appliance.
Wireless Remote:
• Slide the ON/REMOTE/OFF switch to the REMOTE
position. Remove the batteries from the battery tray.
Replace door or decorative barrier front on appliance.
Ignition Module:
• Slide the ON/REMOTE/OFF switch to the REMOTE
position.
Remove the batteries from the battery tray. Replace
door or decorative barrier front on appliance.
BATTERY PACK AND
RESET SWITCH
LOCATED IN
CONTROL CAVITY
RESET SWITCH ON PROPANE APPLICATIONS ONLY
Figure 3.6 Battery Pack Location/Control Cavity
Replace door or decorative
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rave32-ift-bRave36-ift-b

Table of Contents