Vaidnor VDF650 Series User Manual page 177

High-performance ac drive
Table of Contents

Advertisement

Description of Function Codes
Function Code
P5-10
P5-11
P5-12
P5-13
These parameters are used to correct the zero drift of analog output and the output
amplitude deviation. They can also be used to defne the desired AO curve.
If "b" represents zero offset, "k" represents gain, "Y" represents actual output, and "X"
represents standard output, the actual output is: Y = kX + b.
The zero offset coefficient 100% of AO1 and AO2 corresponds to 10 V (or 20 mA). The
standard output refers to the value corresponding to the analog output of 0 to 10 V (or 0 to
20 mA) with no zero offset or gain adjustment.
For example, if the analog output is used as the running frequency, and it is expected that
the output is 8 V when the frequency is 0 and 3 V at the maximum frequency, the gain shall
be set to -0.50, and the zero offset shall be set to 80%.
Function Code
P5-17
P5-18
P5-19
P5-20
P5-21
These parameters are used to set the delay time of output terminals FMR, relay 1, relay 2,
DO1 and DO2 from status change to actual output.
Function Code
P5-22
Parameter Name
AO1 offset coeffcient
AO1 gain
AO2 offset coeffcient
AO2 gain
Parameter Name
FMR output delay time
Relay 1 output delay time
Relay 2 output delay time
DO1 output delay time
DO2 output delay time
Parameter Name
DO valid mode
selection
Setting Range
-100.0%–100.0%
-10.00–10.00
-100.0%–100.0%
-10.00–10.00
Setting Range
0.0–3600.0s
0.0–3600.0s
0.0–3600.0s
0.0–3600.0s
0.0–3600.0s
Setting Range
Unit's digit (FMR valid mode)
0: Positive logic
1: Negative logic
Ten's digit (Relay 1 valid mode)
0, 1 (same as FMR)
Hundred's digit (Relay 2 valid mode)
0, 1 (same as FMR)
Thousand's digit (DO1 valid mode)
0, 1 (same as FMR)
Ten thousand's digit (DO2 valid mode)
0, 1 (same as FMR)
- 176 -
VDF650 User Manual
Default
0.0%
1.00
0.00%
1.00
Default
0.0s
0.0s
0.0s
0.0s
0.0s
Default
00000

Advertisement

Table of Contents
loading