temperature is 25 °C, and the selected power level is Max.
Example of display:
Room temperature 18°
Working power level: Max
Room temperature 24°
Working power level: Min
Setting the power level
1. Press the dial twice during heating operation.
2. The power level will blink.
3. Choose one of the available power levels by turning the
dial.
4. Press the dial once to confirm
Example of display:
Eco mode
When the eco mode is activated, the unit will automatically se-
lect the most convenient working power level from Max to Min,
and will also control the set temperature in order to achieve en-
ergy saving while guaranteeing optimum comfort.
Room temperature 22°
Working power level: Med
Room temperature 25°
The room temperature is
reached the appliance
stops heating
Anti-frost function
This function is useful to prevent freezing.
To activate this function, in manual operation when temperature
is set to 10°C turn the dial anticlockwise till the set point 5 is
displayed and a
will appear.
In this operation mode the working power can not be set.
The appliance will automatically set to Max power level.
If you turn the dial clockwise, you will restore the same power
setting as before being switched to anti-frost.
TIMER OPERATION MODE
In Timer operation mode the unit works according to a pre-set
daily timer program that can be altered to suit your needs.
Turn on the unit by pressing the
button to activate the timer operation mode.
The symbol
will appear on the display together with the
pre-set temperature and power level assigned to the current
time interval.
Daily Timer program
The daily timer program consists of a 24 hour timeline that can
be divided into 96 time intervals of 15 minutes each. It is possi-
ble to associate one of the 2 timer temperature settings to each
time interval, T1 or T2. The time intervals and the temperatures
T1 and T2 can be changed to suit your needs.
Pre-set daily timer program
The default pre-set daily timer program is the following:
T1= 21°C
l
l T2= heating off
T1
T1
21°C
T2
T2
O
2
4
6
0
14
button and then press the
T1
T2
8
10 12 14 16 18 20 22 0 (24)
Time intervals