AXIS M43 Series Panoramic Camera
The device interface
Metadata producers lists the channels used by apps and the metadata they are streaming from the device.
Producer: The app producing the metadata.
Channel: The channel used by the app. Check to enable the metadata stream. Uncheck to disable the stream for compatibility
or resources management reasons.
Detectors
Camera tampering
The camera tampering detector generates an alarm when the scene changes, for example because the lens is covered, sprayed or
severely put out of focus, and the time in Trigger delay has passed. The tampering detector only activates when the camera
has not moved for at least 10 seconds. During this period the detector sets up a scene model to use as a comparison to detect
tampering in current images. For the scene model to be set up properly, make sure that the camera is in focus, the lighting
conditions are correct, and the camera doesn't point at a scene that lacks contours, for example a blank wall. Camera tampering
can be used as a condition to trigger actions.
Trigger delay: Enter the minimum time that the tampering conditions must be active before the alarm triggers. This can help
prevent false alarms for known conditions that affect the image.
Trigger on dark images: It is very difficult to generate alarms when the camera lens is sprayed, since it is impossible to distinguish
that event from other situations where the image turns dark in a similar way, for example when the lighting conditions change.
Turn on this parameter to generate alarms for all cases where the image turns dark. When it's turned off, the device doesn't
generate any alarm when the image turns dark.
Note
For detection of tampering attempts in static and non-crowded scenes.
Accessories
I/O ports
Use digital input to connect external devices that can toggle between an open and closed circuit, for example PIR sensors, door or
window contacts, and glass break detectors.
Use digital output to connect external devices such as relays and LEDs. You can activate connected devices through the VAPIX®
Application Programming Interface or in the device interface.
Port
Name: Edit the text to rename the port.
Direction:
indicates that the port is an input port.
you can click the icons to change between input and output.
Normal state: Click
Current state: Shows the current state of the port. The input or output is activated when the current state is different from the
normal state. An input on the device has an open circuit when it's disconnected or when there is a voltage above 1 V DC.
Note
During restart the output circuit is open. When the restart is complete, the circuit goes back to the normal position. If you
change any settings on this page, the output circuits go back to their normal positions regardless of any active triggers.
open circuit, and
for closed circuit.
indicates that it's an output port. If the port is configurable,
46