Chapter 3
Technical Specifications
Inner Jacket Material
Inner Jacket Diameter
Total Number of Wires
IDU to ODU Cable Standards
Flammability Rating
Standards
IDU to ODU Cable Performance
Frequency Range
Impedance
DC Resistance
Maximum DC Resistance
Capacitance Unbalance
Velocity of Propagation
Propagation Delay Skew
Dielectric Strength
Dielectric Strength to Shield
Minimum Bend Radius
Operating Temperature Range
30
UV resistant FR-PVC
6.1 mm (0.24 in)
8
IEC 60332, UL1581 VW-1
IEC 61156, TIA/EIA-568
1 to 100 MHz
100 Ω
93 Ω/km nominal
95 Ω/km @ 20 °C
1.6 pF/m maximum
68% nominal
35 ns/100 m maximum
700 V/minute
700 V/minute
70 mm (2.8 in)
-40 to 70 °C (-40 to 158 °F)