Venting Introduction 
This wood stove operates on a 
natural draft system, in which the chimney 
system pulls air through the stove.  This unit 
must be installed in accordance with the 
following detailed descriptions of venting 
techniques; not installing the stove in 
accordance with the details listed here can 
result in poor stove performance, property 
damage, bodily injury or death.  Avoid 
make‐shift compromises when installing the 
venting system.  England's Stove Works is 
not responsible for any damage incurred 
due to a poor or unsafe installation. 
Be certain that all aspects of the 
venting system are installed to the venting 
manufacturer's instructions, particularly the 
required clearances to combustibles.  Also, 
be certain to use an attic radiation shield to 
prevent insulation from contacting a 
chimney which passes through an attic. 
The chimney system is the "engine" 
which drives a wood stove, so it is 
imperative for proper unit function that the 
venting system be installed exactly as 
described in the following section. 
 
If questions arise pertaining to the 
safe installation of the stove, our Technical 
Support line (800‐245‐6489) is available.  
Contact your local code official to be certain 
your installation meets local and national 
fire codes, and if you're uncertain about 
how to safely install the stove, we strongly 
recommend contacting a local NFI certified 
installer to perform the installation.  
 
WARNING: Venting system surfaces get HOT, and can cause burns if 
touched.  Noncombustible shielding or guards may be required. 
Page | 8
INSTALLATION
 
Venting Guidelines 
 ALWAYS install vent pipe in strict 
adherence to the instructions and 
clearances included with your 
venting system. 
 DO NOT connect this wood stove to 
a chimney flue which also serves 
another appliance. 
 DO NOT install a flue pipe damper 
or any other restrictive device in the 
exhaust venting system of this unit. 
 USE an approved wall thimble when 
passing through a wall and a ceiling 
support/fire stop when passing 
through a ceiling. 
 INSTALL three sheet metal screws at 
every chimney connector joint.  
 AVOID excessive horizontal runs and 
elbows, as both will reduce the draft 
of the venting system and will result 
in poor stove performance. 
 INSPECT your venting system often, 
to be certain it is clear of creosote, 
fly‐ash and other restrictions. 
 CLEAN the venting system as 
detailed in the maintenance section 
of this manual. 
 ADHERE to the 10‐3‐2 rule regarding 
chimney terminations. 
 INSTALL single wall chimney 
connector with the male end down 
to prevent creosote leakage.  Follow 
double wall chimney connector 
manufacturer's instructions 
regarding proper pipe installation. 