England's Stove Works 50-SVL17 Installation & Operation Manual page 35

Table of Contents

Advertisement

Air Controls: SEE YOUR OWNER'S MANUAL for information on the Proper Use of Air 
Controls (in the Operation section). 
ASH REMOVAL – Follow your Owner's manual's instructions regarding removal and 
disposal of ashes. 
REPLACEMENT of parts that are critical to emissions performance – Follow your Owner's 
manual's instructions regarding replacement of gaskets and other parts that are critical 
to emissions performance. 
Remember: "This wood heater needs periodic inspection and repair for proper operation. It is 
against federal regulations to operate this wood heater in a manner inconsistent with operating 
instructions in this manual." 
More: Burner Tubes – To replace a tube, first be sure that you order the correct tube you need 
to replace.  Then using a 5/16" socket or open end wrench, remove the screw located on the left 
side of the tube.  Be sure to keep the screw.  Push the tube to the right then remove the tube 
(pulling the tube back to the left after that side  has been removed from the hole).  To replace, 
reverse the above procedure...make sure to install the tubes in the correct order. (Front to Back) 
Smoke Detectors 
England's Stove Works, Inc. highly recommends the use of smoke detectors in every room of 
the house.  However, locating a smoke detector directly above this unit can result in nuisance 
This unit is meant to operate only with door closed.  Smoke spillage and an inefficient, lazy 
burn will result from attempting to operate the stove with the door open. 
Additionally, using prohibited fuels can create an unsafe situation and can also generate 
excess carbon monoxide.  Carbon monoxide is an odorless, colorless gas which can be deadly.   
The use of a carbon monoxide detector is strongly recommended. 
 
Compliance:   "This non‐catalytic wood heater meets the 2015 U.S. Environmental 
Protection Agency's crib wood emission limits for wood heaters sold after May 15, 
2015." 
 
Tamper Warning: "This wood heater has a manufacturer‐set minimum low burn rate 
that must not be altered. It is against federal regulations to alter this setting or 
alarms. 
CAUTION 
Page | 35

Advertisement

Table of Contents
loading

This manual is also suitable for:

17-vl50-tvl1717-vlp50-svl17p50-tvl17p