INSTALLATION INSTRUCTIONS
Outline dimension
A
<12000Btu/h
700 210 635 570 65
920 210 635 570 65
>12000Btu/h
How to adjust the air inlet direction?(From rear side to under-side.)
1.
Take off ventilation panel and flange, cut off the staples at
side rail.
Dentilation panel
3.
When install the filter mesh, please plug it into flange inclined
from air return opening, and then push up.
All the figures in this manual are for explanation purpose only. They may be slightly different from the air
conditioner you purchased.The actual unit shall prevail.
Air outlet opening size
B
C
D
E
Air return flange
Air return opening size
F
G
H
493 35
119 595 200 80
713 35
119 815 200 80
2.
Stick the attached seal sponge as per the indicating place in
the following fig, and then change the mounting positions of
air return panel and air return flange .
Side rail
4.
The installation has finish, upon filter mesh which fixing
blocks have been insert to the flange positional holes.
NOTE
18
17
Size of
mounted lug
I
J
K
L
740 350
960 350
Seal sponge
M
Fig.41