Metabo DSSW 475-1/2" Original Instructions Manual page 10

Hide thumbs Also See for DSSW 475-1/2":
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
en
ENGLISH
recommended that you use side grips for air tools
with a straight grip and air tools with a pistol grip. It
is always recommended that you use aids to
absorb the reaction torque.
- Do not touch rotating parts.
- Avoid accidental operation. If the air supply is
interrupted, switch off the air tool using the On/Off
switch.
- Only use lubricants that have been recommended
by the manufacturer.
- Do not use the tool in confined spaces. Be careful
that your hands are not crushed between the air
tool and workpiece, especially when unscrewing.
- Wear personal protective equipment and always
wear safety glasses. By wearing personal protec-
tive equipment such as gloves, protective
clothing, a dust mask, non-skid safety shoes, a
safety helmet or ear protectors, to suit the type of
machine and its use, you reduce the risk of injury.
Wearing this equipment is recommended.
4.4
Risks associated with recurring move-
ments
- When working with the air tool, you may experi-
ence an uncomfortable sensation in your hands,
arms, shoulders, neck or other body parts.
- Make sure you are in a comfortable position to
carry out work with the air tool, check that the tool
is held securely, and avoid any awkward positions
that make it difficult, for example, to keep your
balance. If carrying out work over an extended
period, you/the operator should change position
occasionally. This should help to avoid fatigue and
any unpleasant sensation.
- If the operator experiences persistent symptoms
such as feeling unwell, aches, pains or throbbing,
a prickling or burning sensation, loss of hearing, or
joint stiffening, these warning signs must not be
ignored. The operator should advise the employer
of these symptoms and consult a qualified doctor.
4.5
Risks associated with accessory parts
- Disconnect the air tool from the air supply before
securing or replacing the mounted tool or acces-
sory part.
- Do not touch mounts or accessory parts while
working: this would increase the risk of being cut,
burned or injured as a result of vibrations.
- Only use accessories that are designed for this
device and that fulfil the requirements and the
specifications listed in these operating instruc-
tions.
- Only use mounted tools that are in good condition.
If accessories are defective, they may break and
be ejected during operation.
4.6
Risks in the workplace
- Slipping, tripping and falling are the main reasons
for accidents in the workplace. Pay attention to
surfaces that may have become slippery as a
result of using the air tool, and also be careful that
the air hose does not cause someone to trip.
- Proceed carefully when working in unfamiliar envi-
ronments. Power cables and other supply lines
may represent a hidden risk.
10
- The air tool is not designed for use in explosive
environments and is not insulated against contact
with sources of electric power.
- Ensure that the area where you wish to work is
free of power cables, gas lines or water pipes (e.g.
by using a metal detector).
4.7
Risks associated with dust and vapours
- The dust and vapours generated when the air tool
is used may carry health risks (e.g. cancer, birth
defects, asthma and/or dermatitis); it is therefore
imperative that a risk assessment is carried out in
relation to these risks and that suitable controls
are then implemented.
- The risk assessment should take into account
both the dust generated while the air tool is used
and any existing dust that may be raised during
operation.
- The extracted air must be discharged in such a
way that, in a dust-filled environment, the
minimum of dust is raised.
- If dust or vapours are generated, the main priority
is to control these at the point where they are
released.
- All integral or accessory parts on the air tool that
are designed to collect, extract or prevent airborne
dust or vapours must be used and maintained in
accordance with the manufacturer's instructions.
- Use protective breathing apparatus in accordance
with your employer instructions or in accordance
with health and safety regulations.
4.8
Risks associated with noise
- Failure to use adequate ear protectors when the
noise level is high can result in lasting damage to
hearing, hearing loss and other problems, such as
tinnitus (ringing, whistling or buzzing in the ear).
- It is vital to carry out a risk assessment in relation
to these risks and to implement appropriate
control measures that take the risks into account.
- Appropriate risk control measures may include,
for example, the use of sound-insulating materials
to prevent the knocking sounds that occur on the
workpieces.
- Use ear protection in accordance with your
employer instructions or in accordance with health
and safety regulations.
- The air tool must be operated in accordance with
the recommendations provided in these instruc-
tions and must be maintained in order to avoid
unnecessarily raising the noise level.
- To avoid increasing the noise level unnecessarily,
the consumables and the mounted tool must be
selected, maintained and replaced in accordance
with these instructions.
- The integrated sound absorber must not be
removed. You must ensure the sound absorber is
in good working order.
4.9
Risks associated with vibration
- The effects of vibrations can damage nerves and
impair blood circulation in the hands and arms.
- Keep your hands away from the pin wrench
mounts.

Advertisement

Table of Contents
loading

Table of Contents