Heat Meter; Transport And Storage; Installation - oventrop Multidis SFQ Operating Instructions Manual

Heating circuit distributor/collector
Table of Contents

Advertisement

Available languages

Available languages

Multidis SFQ
- The ball valves item no. 1406483
and 1406484 have a red T-handle
which shall mark the supply pipe.
- The ball valves item no. 1406583
and 1406584 have a blue T-handle
which shall mark the return pipe.
To obtain the length with installed ball
valve, add the length of the Multidis
SFQ heating circuit distributor/col-
lector (L) and the length of the ball
valve (L1).

4.2 Heat meter

Standard heat meters G1 and G¾ can be
installed.
You can obtain the dimensions of
the heat meter from the heat meter
manual.
5.

Transport and storage

Transport the product in its original packaging.
Store the product under the following condi-
tions:
Temperature
-20 °C up to +55 °C
range
Relative
Max. 95%
humidity of air
Particles
Dry and free from dust
Mechanical
Protected from mechani-
influences
cal agitation
Radiation
Protected from UV-rays
and direct sunlight
Chemical
Do not store together
influences
with solvents, chemicals,
acids, fuels or similar
substances
140495281-V01.12.2020
Transport and storage
6.

Installation

The brackets allow mounting on the wall or in
the cabinet.
1. Mount the flow distributor (at the top) and
the return collector (at the bottom) into the
sound-absorbing brackets.
2. Fix the brackets onto the wall or in the
cabinet.
The supply and return pipe can be
connected from either the left or right
hand side.
NOTICE
Damage to property due to
lubricants
Seals can be destroyed by the use of
grease or oils.
f Do not use grease or oil during
installation.
f If necessary, flush dirt particles
and grease and oil residues out of
the pipework.
f When selecting the operating fluid,
observe the general state of the art
(e.g. VDI 2035).
f If the operating fluid is contam-
inated, install a strainer in the
supply pipe (VDI 2035).
23