Electrical Wiring; Line Voltage Wiring - Nordyne VG7TC-FS Installation Instructions Manual

Two-stage condensing gas furnaces with fixed & variable speed blowers
Table of Contents

Advertisement

Conversion to LP / Propane is detailed in the installation
instructions provided with the conversion kit. Generally,
this will require the replacement of the burner orifices and
the spring assembly in the pressure regulator. Approved
conversion kits are listed below:
• Installations in the United States: For Propane (LP)
conversion or for LP gas installations in altitudes between
2,000 ft. and 10,000 ft. above sea level, use the LP &
High Altitude LP Gas Conversion Kit (P/N 904914) for
Installations in the United States. Please follow the
instructions provided with the kit.
• Installations in Canada: For Propane (LP) conversion or
for LP Gas installations in altitudes between zero and
4,500 ft. above sea level, use the LP & High Altitude
LP Gas Conversion Kit (P/N 904915) for Installations
in Canada. Please follow the instructions provided
with the kit.
If the installation is in the U.S. above 2,000 ft., refer to
Table 11 (page 37)
to determine the correct orifice size
and regulator pressure. See the example below.
When conversion is complete, verify the manifold pressure
and input rate are correct as listed in the Tables.
Installation Example
Elevation: ............................................... 5,000 feet
Type of Gas: ........................................... Propane Gas
Input BTUH of Furnace: ......................... 80,000
From
Table
11, find 5,000 and follow across the row; stop
at the 80,000 btuh column. At first stage, the manifold
pressure listed is 4.2, but at 2nd stage the pressure is
9.0. The listed orifice size is 56..
24

ELECTRICAL WIRING

WARNING:
ELECTRICAL SHOCK,FIRE OR EXPLOSION
HAZARD
Failure to follow safety warnings exactly could
result in serious injury or property damage.
Improper servicing could result in dangerous
operation, serious injury, death or property
damage.
• Before servicing, disconnect all electrical
power to furnace.
• When servicing controls,label all wires prior
to disconnecting.Reconnect wires correctly.
• Verify proper operation after servicing."
AVERTISSEMENT:
RISQUEDECHOCÉLECTRIQUE,D'INCENDIE
OU D'EXPLOSION
Le non-respect des avertissements de sécurité
pourrait entraîner un fonctionnement dangereux
de l'appareil, des blessures graves, la mort ou
des dommages matériels.
Un entretein incorrect pourrait entraîner un
fonctionnement dangereux de l'appareil, des
blessures graves, la mort ou des dommages
matériels
• Couper toute alimentation électrique au
générateur d'air chaud avant de prodéder
aux travaux d'entretein.
• Au moment de l'entretien des commandes,
étiquetez tous les fils avant de les débrancher.
S'assurer de les raccorder correctement.
• S'assurer que l'appareil fonctionne
adéquatement aprés l'entretien.
• Electrical connections must be in compliance with all
applicable local codes, and the current revision of the
National Electric Code (ANSI/NFPA 70).
• For Canadian installations the electrical connections
and grounding shall comply with the current Canadian
Electrical Code (CSA C22.1 and/or local codes).

Line Voltage Wiring

It is recommended that the line voltage (115 VAC) to
the furnace be supplied from a dedicated branch circuit
containing the correct fuse or circuit breaker for the furnace.
See
Table 5, (page
25).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents