High Altitude Application (Natural Gas Only); Converting From Natural Gas To Lp / Propane - Nordyne VG7TC-FS Installation Instructions Manual

Two-stage condensing gas furnaces with fixed & variable speed blowers
Table of Contents

Advertisement

WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury or property damage.
Never test for gas leaks with an open flame.
Use a commercially available soap solution
made specifically for the detection of leaks
to check all connections. A fire or explosion
may result causing property damage,personal
injury or loss of life.
After the gas piping to the furnace is complete, all
connections must be tested for gas leaks. This includes
pipe connections at the main gas valve, emergency
shutoff valve and flexible gas connectors (if applicable).
The soap and water solution can be applied on each
joint or union using a small paintbrush. If any bubbling is
observed, the connection is not sealed adequately and
must be retightened. Repeat the tightening and soap
check process until bubbling ceases.
IMPORTANT NOTE
When pressure testing gas supply lines at pressures
greater than 1/2 psig (14 inch W.C.), the gas supply
piping system must be disconnected from the furnace
to prevent damage to the gas control valve. If the test
pressure is less than or equal to 1/2 psig (14 inch
W.C.), close the manual shut-off valve.

High Altitude Application (Natural Gas Only)

The installation of this furnace at altitudes above 2,000
feet must meet the requirements of the National Fuel Gas
Code or local jurisdiction. In Canada, the requirements for
high altitude are different and governed by CGA B149.1.
Please consult your local code authority.
WARNING:
The reduction of input rating necessary for high
altitude installation may only be accomplished
with factory supplied orifices. Do not attempt to
drill out orifices in the field. Improperly drilled
orifices may cause fire, explosion, carbon
monoxide poisoning, personal injury or death.
The furnaces are shipped from the factory with orifices
and gas regulator settings for natural gas operation at sea
level altitudes. At 2,000 feet, the NFGC requires that this
appliance be derated 4% for each 1,000 feet of altitude.
For example, the input needs to be reduced 8% at 2,000
feet, 12% at 3,000 feet, etc. This deration is in reference
to the input rate and gas heating value at sea level.
To derate the furnace requires knowing the heating value of
the gas at the installation site. Heating values at particular
job sites vary for two reasons:
1. The chemical mixture of the gas varies from region to
region and is expressed as the "sea level heating value".
2. The heating value varies by altitude. For this reason,
particularly in high altitude areas, the local gas utility
usually specifies the heating value at the residence's
gas meter as the "local value".
For added flexibility, two tables have been provided for
natural gas installations with high or low heating values
at sea level.
Table 13
&
the orifice sizes and manifold pressure to use at various
altitudes.
Table 13
(HIGH) is for natural gas installations
with a heating value of more than 1,000 Btu per cubic foot
and
Table 14
(LOW) is for less than 1,000 Btu per cubic
foot. To determine which table to use:
1. Consult your local utility for the local heating value at
your installation.
2. From
Table 12 (page
value as supplied by the utility company. Follow down
the column and stop at your altitude level.
3. If your sea level heating value is HIGH, use
or if it's LOW, use
Table
Installation Example
Elevation: .................................................. 5,000 feet
Type of Gas: ........................................... Natural Gas
Local Heating Value of Gas: .............................. 750
From
Table
12, find 750 and follow down the column,
stop at the 5,000 feet row. The heating value listed is
LOW.
Table 14
will be used to determine orifice size
and manifold pressure.
After changing the regulator pressure or changing the
orifices, it is required that you measure the gas input rate.
This may be accomplished in the usual way, by clocking
the gas meter and using the local gas heating value. See
Verifying & Adjusting the Input Rate section
IMPORTANT NOTE
Observe the action of the burners to make sure there
is no yellowing, lifting or flashback of the flame.

Converting from Natural Gas to LP / Propane

WARNING:
The furnace was shipped from the factory
equipped to operate on natural gas.Conversion
to LP / Propane gas must be performed by
qualified service personnel using a factory
supplied conversion kit. Failure to use the
proper conversion kit can cause fire, explosion,
property damage, carbon monoxide poisoning,
personal injury, or death.
Table 14 (page 38)
contain
37), find your local heating
Table 13
14. See example.
(page
28).