Maintenance (only by authorised service technician)
NOTICE: Damage to the appliance.
Damage to the heat exchanger.
▶ Do not apply a jet that is too strong or
aimed in a direction other than that
indicated.
▶ If the soot is not removed use a stiff brush to carefully clean
the fins.
▶ Regions with average/high water hardness: descale the
inside of the heat exchanger and the connection pipes by
using a diluted solution of hydrochloric acid or white
vinegar.
▶ When reinstalling the heat exchanger replace the o-rings
and seals.
Burner
▶ Inspect the burner and clean it if necessary.
If cleaning is required:
▶ Dismantle the burner.
▶ Use a brush to clean the surface of the burner elements.
▶ Use a jet of air to blow the burner elements.
Water filter
▶ Close the cold water inlet isolation valve.
▶ Loosen the cold water pipe.
▶ Carefully remove the water filter.
▶ Replace with a new water filter.
6.3
Replacement of the fuse (electronic control

unit)

▶ Loosen the fixing screw of the electronic control unit
▶ Release all the connections to the electronic control unit
▶ Open the electronic control unit
▶ Replace the fuse located in the corner of the circuit board.
6.4

Start-up after completion of maintenance

▶ Re-tighten all of the connections.
▶ Check the burner pressure.
▶ Check air tightness of the flue circuit with the front cover
fitted.
▶ Check that there are no gas or water leaks.
6.5

Safe operation/ risk for prolonged use

Prolonged use power wear some elements may cause gas leaks
and transhipment of products of combustion.
Preventively should:
▶ Make a visual inspection of the maintenance intervals to the
following elements:
– Electrical contact of security sensor
22
– Fan
– Gas valve
– Combustion chamber
In case of corrosion visible:
▶ Call the intervention of a qualified contractor.