CHERUBINI DOGE RX Instructions Manual

Tubular motor with electronic limit switch for venetian blinds

Advertisement

Quick Links

DOGE RX
MOTORE TUBOLARE CON FINECORSA ELETTRONICO
IT
PER VENEZIANE
TUBULAR MOTOR WITH ELECTRONIC LIMIT SWITCH
EN
FOR VENETIAN BLINDS
RAFFSTOREN - ROHRMOTOR MIT
DE
ELEKTRONISCHER ENDLAGENEINSTELLUNG
MOTEUR TUBULAIRE POUR BRISE SOLEIL ORIENTABLE (BSO)
FR
AVEC CONTACT DE FINS DE COURSE ÉLECTRONIQUES
MOTOR TUBULAR PARA VENECIANA DE LAMAS ORIENTABLES
ES
CON FIN DE CARRERA ELECTRÓNICO
ISTRUZIONI - INSTRUCTIONS - EINSTELLANLEITUNGEN
INSTRUCTIONS - INSTRUCCIONES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DOGE RX and is the answer not in the manual?

Questions and answers

Summary of Contents for CHERUBINI DOGE RX

  • Page 1 DOGE RX MOTORE TUBOLARE CON FINECORSA ELETTRONICO PER VENEZIANE TUBULAR MOTOR WITH ELECTRONIC LIMIT SWITCH FOR VENETIAN BLINDS RAFFSTOREN - ROHRMOTOR MIT ELEKTRONISCHER ENDLAGENEINSTELLUNG MOTEUR TUBULAIRE POUR BRISE SOLEIL ORIENTABLE (BSO) AVEC CONTACT DE FINS DE COURSE ÉLECTRONIQUES MOTOR TUBULAR PARA VENECIANA DE LAMAS ORIENTABLES CON FIN DE CARRERA ELECTRÓNICO...
  • Page 3: Table Of Contents

    TRANSLATION OF THE ORIGINAL INSTRUCTIONS Table of contents: How to prepare the motor ..................p. 22 Electrical connections ..................... p. 23 Compatible remote controls ................... p. 24 Key to symbols ....................p. 24-25 Command sequences example ................p. 25 Function open/close programming remote control ..........p. 26-27 Setting the first remote control ................
  • Page 4: How To Prepare The Motor

    HOW TO PREPARE THE MOTOR STOP RING NUT ADAPTOR DRIVING PULLEY STOP RING NUT 1. Insert the adaptor in the stop ring nut mating the groove with the reference notch and push till they touch. 2. Fix the driving pulley on the motor pin until the stop pin clicks.
  • Page 5: Electrical Connections

    ELECTRICAL CONNECTIONS - In order to prevent dangerous situations or malfunctioning, the electrical command elements wired to the motor must be sized according to the motor’s electrical features. - Means for disconnection must be incorporated in the fixed wiring in accordance with the national installation standards.
  • Page 6: Compatible Remote Controls

    COMPATIBLE REMOTE CONTROLS GIRO GIRO Wall stop DOWN down STOP GIRO Lux GIRO P-Lux DISPLAY GIRO Plus DISPLAY Activating the Change channel DISPLAY Change Sun sensor channel Wind sensor Wind sensor is “ON” is “ON” Sun sensor is “ON” Sun sensor is “ON” Change Activating/ Deactivating the Sun sensor Deactivating the Sun sensor...
  • Page 7: Command Sequences Example

    KEY TO SYMBOLS short motor rotation in one direction Press button A long motor rotation in other direction DOWN double short rotation Press buttons A and B at the same time COMMAND SEQUENCES EXAMPLE Most of the command sequences have three distinct steps, at the end of which the motor indicates if the step has been concluded positively or not, by turning in different ways.
  • Page 8: Function Open/Close Programming Remote Control

    FUNCTION OPEN/CLOSE PROGRAMMING REMOTE CONTROL SKIPPER PLUS - SKIPPER LUX - SKIPPER P-LUX REMOTE CONTROL POP PLUS - POP LUX - POP P-LUX To prevent accidental changes to the programming of the motor during the daily use of the remote control, the possibility of programming is disabled automatically 8 hours after sending the last sequence (A+B or B+C).
  • Page 9 FUNCTION OPEN/CLOSE PROGRAMMING REMOTE CONTROL SKIPPER - SERIES GIRO - REMOTE CONTROL POP To prevent accidental changes to the programming of the motor during the daily use of the remote control, the possibility of programming is disabled automatically 8 hours after sending the last sequence (A+B or B+C).
  • Page 10: Setting The First Remote Control

    SETTING THE FIRST REMOTE CONTROL This operation can only be performed when the motor is new, or after a total delete of the memory. During this step, power up only one motor at time! T1: First remote control to be set T1 (2 sec) AUTOMATIC DISABLING OF THE FIRST REMOTE CONTROL SETTING FUNCTION...
  • Page 11: Setting Of The Limit Switches

    SETTING OF THE LIMIT SWITCHES Tubular motors have an electronic limit switch system with an encoder. This system ensures great reliability and precision in keeping the positions. Limit switch regulation is performed simply with the remote control. During setting, the motor moves only as long as the up or down button is pressed, stopping when the button is released.
  • Page 12: Deleting The Limit Switch Positions

    DELETING THE LIMIT SWITCH POSITIONS HIGH LIMIT SWITCH DELETING To delete only the high limit switch, carry out the following procedure and proceed with the ‘HIGH LIMIT SWITCH SETTING’. Tn: Already programmed remote control Tn (2 sec) LOW LIMIT SWITCH DELETING To delete only the low limit switch, carry out the following procedure and proceed with the ‘LOW LIMIT SWITCH SETTING’.
  • Page 13: Setting A Middle Position

    SETTING A MIDDLE POSITION This function allows to drive the venetian blind to a favourite middle position. To memorize the middle position, move the venetian blind to the desired position and then hold the STOP button down (for about 4 seconds) until the motor gives confirmation. Tn: Already programmed remote control Tn (4 sec) When the intermediate position is memorised, you can...
  • Page 14: Slat Opening Control

    SLAT OPENING CONTROL You can give the slat opening command when the engine is stopped; it is sufficient to: - on the REMOTE CONTROL briefly press button B (stop) (< 2 sec.) < 2 sec - via the BUTTON press DOWN very long (> 2 sec.) DOWN >...
  • Page 15: Setting Of Additional Remote Controls

    SETTING OF ADDITIONAL REMOTE CONTROLS Up to 15 remote controls can be set. Tn: Already programmed remote control Tx: Additional remote control Tx (2 sec) REMOTE CONTROL MEMORY CLEARING It is possible to delete singly all the memorized remote controls. When the last one is deleted the motor initial condition is restored.
  • Page 16: Total Deletion Of The Remote Controls Memory

    TOTAL DELETION OF THE REMOTE CONTROLS MEMORY This full memory clearing does not delete the setting of the limit switch. The full memory clearing can be performed in two ways: 1) WITH THE REMOTE CONTROL Tn: Already programmed remote control Tn (4 sec) 2) WITH THE WHITE WIRE Do this operation only in case of emergency, if all remote controls are no longer operating.
  • Page 17: Special Functions

    SPECIAL FUNCTIONS SHORT-TERM SETTING OF A REMOTE CONTROL This function makes it possible to store a remote control temporarily, for example, with the purpose of setting the limit switches during assembly in the factory. A later final saving of the remote control will be possible using the appropriate command sequence (see: “SETTING THE FIRST REMOTE CONTROL”).
  • Page 18: Operation With Wind Sensor

    OPERATION WITH WIND SENSOR It is possible to associate a wind sensor with the motor. In the presence of a wind alarm, the motor performs the following operations: Event Automatic movement Wind alarm (wind The Venetian blind raises completely and cannot be stopped or above threshold) lowered until 8 minutes after the wind speed has returned below Default function.
  • Page 19: Setting The Wind Sensor

    SETTING THE WIND SENSOR To associate the sensor to the motor, a remote control must be already memorized. The setting sequence is the following: Tn: Already programmed remote control 2 sec DELETING THE SENSOR To delete the sensor from the motor, an already programmed remote control must be used.
  • Page 20: Command Management From White Wire

    COMMAND MANAGEMENT FROM WHITE WIRE UP-DOWN / UP-DOWN “DEAD MAN” NB: The default function provided in the motors leaving the factory is UP-DOWN double button switch. It is always possible to change the command type setting by performing the sequence below.
  • Page 21: Eu Declaration Of Conformity

    Il testo completo della dichiarazione di conformità UE è disponibile facendone richiesta sul sito: www.cherubini.it. EU DECLARATION OF CONFORMITY CHERUBINI S.p.A. declares that the product is in conformity with the relevant Union harmonisation legislation: Directive 2014/53/EU, Directive 2011/65/EU. The full text of the EU declaration of conformity is available upon request at the following website: www.cherubini.it.