3.4 Basic Settings & Interface Settings
Go to Device > Setting > General Settings to change the reporting interval, etc.
Parameters
Reporting interval of transmitting current sensor values to network server.
Reporting Interval
Default: 10 min
Change the temperature unit displayed on the ToolBox.
Note:
Temperature Unit
1) The temperature unit in the reporting package is fixed as °C.
2) Please modify the threshold settings if the unit is changed.
Change the password for ToolBox App or software to read/write this
Change Password
device.
For LEO-S552-THG0-DI, go to Device > Settings > Interface Settings to modify
configurations.
Parameters
Change the interface type of GPIO interface. Counter and Digital is
Interface Type
available, counter as default.
When the function is enabled, pulse with a rate of more than 250us can
Pulse Filter
be counted.
Modify Count Value
Set the initial counting value.
www.advantech.com
Description
Description
11 1 1

Advertisement

Table of Contents
loading