Ceiliing-mounted air unit heating/cooling (24 pages)
Summary of Contents for REMKO RTV Series
Page 1
Operating manual REMKO RTV series High-performance fans for the construction and renovation industry RTV 20, RTV 35 0209-2019-02 Edition 1, en_GB Read the instructions prior to performing any task!
Page 2
Read these operating instructions carefully before commis- sioning / using this device! These instructions are an integral part of the system and must always be kept near or on the device. Subject to modifications; No liability accepted for errors or mis- prints! Translation of the original operating manual...
Table of contents Safety and usage instructions......................4 1.1 General safety notes........................4 1.2 Identification of notes........................4 1.3 Personnel qualifications........................4 1.4 Dangers of failure to observe the safety notes................4 1.5 Safety-conscious working....................... 4 1.6 Safety instructions for the operator....................5 1.7 Safety notes for installation, maintenance and inspection work............
REMKO RTV series Safety and usage instructions CAUTION! This combination of symbol and signal word 1.1 General safety notes warns of a potentially hazardous situation, which if not avoided may cause injury or mate- Carefully read the operating manual before com- rial and environmental damage.
1.6 Safety instructions Wear hearing protection if spending a longer period of time in the vicinity of the unit. for the operator The units must be inspected by a service tech- The operational safety of the units and compo- nician to ensure that they are safe to use and nents is only assured providing they are used as fully functional at least once yearly.
Disposal of equipment and components plete and return the "certificate of warranty" to REMKO GmbH & Co. KG at the time when the Only recyclable materials are used in the manufac- units are purchased and commissioned.
Thanks to The units of the RTV series can be used in three its specially adapted air ducting, the turbo fans different installation angles (0°, 45° and 90°).
REMKO RTV series Electrical wiring Commissioning The 230V electrical connection is made using a Before the initial commissioning built-in mains cable with earthed safety plug. Check that the unit and any accessories being Connect the power plug to a properly installed used are installed correctly.
Shutdown Commissioning Connect unit Move the operating switch to the “0” position. Switch unit to desired power stage using the 2- If required, read off and record the operating stage operating switch. hours on the operating hours counter. With longer breaks in operation: Disconnect the unit from the power supply.
REMKO RTV series Care and maintenance General notes Regular care and maintenance is fundamental to a long service life and fault-free operation of the unit. In normal operation, the units are almost mainte- nance-free. However, in order to guarantee contin-...
General view of unit and spare parts 8.1 Exploded view of the unit RTV20 We reserve the right to modify the dimensions and design as part of the ongoing technical development process. 8.2 Spare parts list RTV20 No. Designation RTV20 EDP no.
REMKO RTV series 8.3 Exploded view of the unit RTV35 We reserve the right to modify the dimensions and design as part of the ongoing technical development process. 8.4 Spare parts list RTV35 No. Designation RTV35 EDP no. Protective intake grille...
Need help?
Do you have a question about the RTV Series and is the answer not in the manual?
Questions and answers