REMKO RAV 35 Operating Instructions Manual
REMKO RAV 35 Operating Instructions Manual

REMKO RAV 35 Operating Instructions Manual

High-perfomance fans for the construction and renovation industry

Advertisement

Quick Links

Operating instructions

REMKO RAV 35
High-performance fans
for the construction and renovation industry
Read the instructions prior to performing any task!
0190-2018-07 Edition 1, en_GB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RAV 35 and is the answer not in the manual?

Questions and answers

Summary of Contents for REMKO RAV 35

  • Page 1: Operating Instructions

    Operating instructions REMKO RAV 35 High-performance fans for the construction and renovation industry Read the instructions prior to performing any task! 0190-2018-07 Edition 1, en_GB...
  • Page 2 Read these operating instructions carefully before commis- sioning / using this device! These instructions are an integral part of the system and must always be kept near or on the device. Subject to modifications; No liability accepted for errors or mis- prints! Translation of the original operating instructions...
  • Page 3: Table Of Contents

    Table of contents Safety and usage instructions......................4 1.1 General safety notes........................4 1.2 Identification of notes........................4 1.3 Personnel qualifications........................4 1.4 Dangers of failure to observe the safety notes................4 1.5 Safety-conscious working....................... 4 1.6 Safety instructions for the operator....................5 1.7 Safety notes for installation, maintenance and inspection work............
  • Page 4: Safety And Usage Instructions

    REMKO RAV Safety and usage instructions CAUTION! This combination of symbol and signal word 1.1 General safety notes warns of a potentially hazardous situation, which if not avoided may cause injury or mate- Carefully read the operating manual before com- rial and environmental damage.
  • Page 5: Safety Instructions For The Operator

    1.6 Safety instructions for the oper- Wear hearing protection if spending a longer period of time in the vicinity of the unit. ator The units must be inspected by a service tech- The operational safety of the units and compo- nician to ensure that they are safe to use and nents is only assured providing they are used as fully functional at least once yearly.
  • Page 6: Unauthorised Modification And Changes

    Disposal of equipment and components plete and return the "certificate of warranty" to REMKO GmbH & Co. KG at the time when the Only recyclable materials are used in the manufac- units are purchased and commissioned.
  • Page 7: Technical Data

    Technical data 2.1 Unit data Unit type RAV 35 Configuration Axial fan 2-speed air flow rate 1350/2900 Pressure, max. Electrical wiring V/~/Hz 230/1~/50 Max. power consumption Customer-provided electrical protection Max. current consumption Sound pressure level 5 m *) dB(A) Max. temperature of conveyed medium °C...
  • Page 8: Characteristic Curves

    REMKO RAV 2.2 Characteristic curves 1000 1500 2000 2500 3000 3500 Fig. 1: Characteristic curves 1: Pressure build-up [Pa] 2: Medium flow rate [m A: Characteristic curve for the smaller stage B: Characteristic curve for the higher stage Measurement carried out per DIN EN ISO 5801 – Test set-up category B.
  • Page 9: Electrical Wiring

    Electrical wiring Commissioning The 230V electrical connection is made using a Before the initial commissioning built-in mains cable with earthed safety plug. Check that the unit and any accessories being Connect the power plug to a properly installed used are installed correctly. and appropriately safeguarded mains socket.
  • Page 10: Motor Overload Protection Switch

    REMKO RAV Motor overload protec- Shutdown tion switch Move the operating switch to the “0” position. Read off the operating hours counter if The unit is equipped with a motor overload protec- required. tion switch (MS), which interrupts the power supply...
  • Page 11: Care And Maintenance

    Care and maintenance General notes Regular care and maintenance is fundamental to a long service life and fault-free operation of the unit. In normal operation, the units are almost mainte- nance-free. However, in order to guarantee contin- uous fault-free operation, they should be checked at regular intervals and cleaned or repaired when necessary and in accordance with the respective operating conditions.
  • Page 12: General View Of Unit And Spare Parts

    REMKO RAV General view of unit and spare parts 9.1 Exploded view of the unit We reserve the right to modify the dimensions and design as part of the ongoing technical development process. 9.2 Spare parts list No. Designation EDP no.
  • Page 13: Index

    Index Care ....... . . 11 Safety Care and maintenance ....11 Dangers of failure to observe the safety Commissioning .
  • Page 14 REMKO RAV...
  • Page 16 SFlb Customer Service Our equipment operates precisely and reliably. However, in the event of a fault, REMKO customer service is quickly at the scene. Our comprehensive network of experienced dealers always guarantees quick and REMKO GmbH & Co. KG reliable service.

Table of Contents