REMKO PWL Series Operating And Installation Instructions

REMKO PWL Series Operating And Installation Instructions

Ceiling-mounted ventilation unit
Hide thumbs Also See for PWL Series:

Advertisement

Quick Links

Operating and
installation instructions
REMKO PWL series
Ceiling-mounted ventilation unit
PWL 101-H, PWL 102-H, PWL 103-H, PWL 201-H, PWL 202-H, PWL 203-H
PWL 301-H, PWL 302-H, PWL 303-H, PWL 101-HK, PWL 102-HK, PWL 103-HK
PWL 201-HK, PWL 202-HK, PWL 203-HK, PWL 301-HK, PWL 302-HK, PWL 303-HK
Edition EN - X07
Read the instructions prior to performing any task!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PWL Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for REMKO PWL Series

  • Page 1 Operating and installation instructions REMKO PWL series Ceiling-mounted ventilation unit PWL 101-H, PWL 102-H, PWL 103-H, PWL 201-H, PWL 202-H, PWL 203-H PWL 301-H, PWL 302-H, PWL 303-H, PWL 101-HK, PWL 102-HK, PWL 103-HK PWL 201-HK, PWL 202-HK, PWL 203-HK, PWL 301-HK, PWL 302-HK, PWL 303-HK...
  • Page 3: Table Of Contents

    Content Planning notes Safety notes Unit description Unit installation Installation examples Electrical wiring Hydraulic connection Commissioning Shutdown Care and maintenance Repair Fan motor Condensate pump Unit dimensions Performance tables / technical data PWL 101-103 Performance tables / technical data PWL 201-203 Performance tables / technical data PWL 301-303 Intended use Customer service and guarantee...
  • Page 4: Planning Notes

    REMKO PWL Planning notes Safety notes In order to achieve an optimum Cooling mode The units were subjected to comfortable temperature in a extensive material, functional and room, the planning of the room The following data is required to quality inspections prior to delivery.
  • Page 5: Unit Description

    Unit description The units must be installed away The units are stationary, indirectly The tube heat exchangers are ■ from traffic zones and installed fuelled recirculation cooling/ made of copper tubes with by crane, for example heating units with Cu/Al finned aluminium fins on top.
  • Page 6: Unit Installation

    REMKO PWL Unit installation Make sure that no one is under the suspended load during installation! For safe unit installation, observe Use the template supplied in the packaging to mark the fastening points. the following instructions: Ensure that there is sufficient space between the unit and ceiling for the media connections.
  • Page 7: Installation Examples

    Installation examples Heating mode The units are designed for use in both high and low-ceilinged rooms. Low-ceilinged rooms; horizontal discharge High-ceilinged rooms; vertical discharge The fan’s direction of rotation can be changed (pole switching) in order to adjust the air direction individually to the structural or personal requirements.
  • Page 8: Electrical Wiring

    REMKO PWL Electrical wiring Hydraulic connection The electrical unit connections may Connecting several units Connection to the on-site only be established by authorised hydraulic system specialists in accordance with the If required, several units (also of applicable regulations, observing different sizes) can be operated...
  • Page 9: Commissioning

    Commissioning Drainage when at risk of Before initial commissioning freezing CAUTION Note that if using a speed ■ Complete static drainage of controller (accessory), the Commissioning can only take the finned heat exchangers is regulating device output must place once it has been assured not possible in the condition as be attuned to the total output that the proper assembly...
  • Page 10: Shutdown

    REMKO PWL Care and maintenance The units are basically During initial commissioning Ensure that no more ■ maintenance-free. Perform a visual condensate is formed, as inspection on the units and finned All regulating, control and safety the condensate pump is also...
  • Page 11: Repair

    Repair If the finned heat exchanger ■ NOTE CAUTION surface is coated with greasy or Repair and maintenance work Prior to maintenance or repair sooty particles, the exchanger may only be carried out by work, the unit must be discon- element can be removed and authorised and qualified tech- nected from the mains power...
  • Page 12: Fan Motor

    REMKO PWL 400 V / 2-speed fan motor CAUTION Connection diagram The electrical unit connection High speed Low speed hohe Drehzahl niedere Drehzahl must be established by - Schaltung Δ - switching - Schaltung Y - switching ∆ authorised specialists in accordance with DIN EN 60335-1 and VDE 0116.
  • Page 13: Unit Dimensions

    Unit dimensions NOTE Hydraulic connection R 1“ "A" The supply and return lines can  be connected in any way Condensate hose Condensate pump View "A" Dimen- PWL 101-103 HK PWL 201-203 HK PWL 301-303 HK sions 985 mm 1084 mm 1178 mm 632 mm 963 mm...
  • Page 14: Performance Tables / Technical Data Pwl 101-103

    REMKO PWL PWL 101-103 - Heating • Performance tables • Technical data Type PWL 101-H PWL 102-H PWL 103-H Version 2-speed 2-speed 2-speed Speed Electrical connection 400/3~N Frequency Power consumption 0.1/0.07 Nominal current 0.26/0.13 Air volume m³/h 2030 1685 1960...
  • Page 15 PWL 101-103 - Cooling • Performance tables • Technical data Type PWL 101-HK PWL 102-HK PWL 103-HK Version 2-speed 2-speed 2-speed Speed Electrical connection 400/3~N Frequency Power consumption 0.1/0.07 Nominal current 0.26/0.13 Air volume m³/h 2030 1685 1960 1610 1885 1530 Sound pressure level dB (A)
  • Page 16: Performance Tables / Technical Data Pwl 201-203

    REMKO PWL PWL 201-203 - Heating • Performance tables • Technical data Type PWL 201-H PWL 202-H PWL 203-H Version 2-speed 2-speed 2-speed Speed Electrical connection 400/3~N Frequency Power consumption 0.28/0.18 Nominal current 0.67/0.37 Air volume m³/h 3110 2580 2900...
  • Page 17 PWL 201-203 - Cooling • Performance tables • Technical data Type PWL 201-HK PWL 202-HK PWL 203-HK Version 2-speed 2-speed 2-speed Speed Electrical connection 400/3~N Frequency Power consumption 0.28/0.18 Nominal current 0.67/0.37 Air volume m³/h 3110 2580 2900 2400 2850 2350 Sound pressure level dB (A)
  • Page 18: Performance Tables / Technical Data Pwl 301-303

    REMKO PWL PWL 301-303 - Heating • Performance tables • Technical data Type PWL 301-H PWL 302-H PWL 303-H Version 2-speed 2-speed 2-speed Speed Electrical connection 400/3~N Frequency Power consumption 0.36/0.22 Nominal current 0.84/0.46 Air volume m³/h 4300 2650 4150...
  • Page 19 PWL 301-303 - Cooling • Performance tables • Technical data Type PWL 301-HK PWL 302-HK PWL 303-HK Version 2-speed 2-speed 2-speed Speed Electrical connection 400/3~N Frequency Power consumption 0.36/0.22 Nominal current 0.84/0.46 Air volume m³/h 4300 2650 4150 2400 3900 1710 Sound pressure level dB (A)
  • Page 20: Intended Use

    “Certificate of guarantee” to Our units are carefully packed The units must only be operated REMKO GmbH & Co. KG at the and delivered in stable transport by appropriately instructed time when the units are purchased packaging and, if applicable, personnel.
  • Page 21: View Of The Unit

    View of the unit Spare parts list Designation PWL 101-103 HK PWL 201-203 HK PWL 301-303 HK Heat exchanger assy. 1 1110700 1110711 1110722 Heat exchanger assy. 2 1110701 1110712 1110723 Heat exchanger assy. 3 1110702 1110713 1110724 Electr. terminal box 1110703 1110714 1110725...
  • Page 22: Legend / Usable Limits

    REMKO PWL Legend / usable limits Finned heat exchanger The CU/AL finned heat exchangers are comprised of copper tubes with fitted aluminium fins. The connection pipes made of steel tubing are guided out of the housing on the angled sides. The non-twist connections are equipped with a 1˝...
  • Page 23: Technical Data

    Technical data Series PWL 101-103 HK PWL 201-203 HK PWL 301-303 HK Electrical connection 400/3~N 400/3~N 400/3~N Frequency Power consumption 0.10/0.07 0.28/0.18 0.36/0.22 Nominal current 0.26/0.13 0.67/0.37 0.84/0.46 Speed 920/750 920/750 920/750 2030/1685 3110/2580 4300/2650 Ventilation capacity for assembly 1 1960/1610 2900/2400 4150/2400...
  • Page 24 REMKO QUALITY WITH SYSTEMS Air-Conditioning | Heating | New Energies REMKO GmbH & Co. KG Telephone +49 (0) 5232 606-0 Hotline within Germany Telefax +49 (0) 5232 606-260 +49 (0) 5232 606-0 Klima- und Wärmetechnik Im Seelenkamp 12 E-mail info@remko.de...