The power LED is blinking and no connection can be
made?
If the power LED blinks red and no WAN connections can be
established, there is no cause for concern. This merely means
that a pre-set charge or time limit has been reached.
There are three ways to remove the lock:
Reset the toll protection.
Increase the limit.
Deactivate the lock completely (set limit to '0').
LANmonitor shows you when a charge or time limit has been reached. To reset the toll protec-
tion, activate the context menu (right-mouse click) Reset charge and time limits. The charge
settings are defined in LANconfig under Management
able if the 'Complete configuration display' is activated under Tools
With WEBconfig, charge protection and all parameters are to be found under LCOS menu tree
Setup
Charges
·
Fan
The Fan LED displays the fan's status:
Green
Orange
Red
To prevent damage to the hardware, this LED is complemented by an acoustic
signal. If the fan is blocked or the CPU temperature exceeds 60°, a pulsed
acoustic signal is emitted.
16
The power LED blinks alternately in red/green until a configuration
password has been set. Without a configuration password, the con-
figuration data in the LANCOM is unprotected. Normally you would
set a configuration password during the basic configuration (instruc-
tions in the following chapter). Information about setting a configu-
ration password at a later time is available in the section 'The Security
Wizard'.
Reset budgets.
On (permanently)
On (permanently)
blinking
Costs (these settings are only avail-
CPU temperature OK
CPU temperature > 55°
Hardware failure of the fan or CPU temperature > 60°;
additional acoustic signal
Signal that a
charge or time
limit has been
reached
Options).