Installation guidelines

TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER
PANEL TO AVOID ELECTRICAL SHOCK.
• The installation must be performed by a qualified electrician and must
comply with electrical codes of your region.
• Do NOT install the thermostat in an area where it can be exposed to water or
rain.
• Avoid locations where there are air drafts (such as the top of a staircase or
an air outlet), dead air spots (such as behind a door), or direct sunlight.
• Do not install the thermostat on a wall section that conceals air ducts,
chimney pipes or stove pipes.
• Install the thermostat about 1.5 m (5 feet) high, on an inside wall facing the
heater.
• Install the thermostat onto an electrical box.
• This thermostat has tinned copper wires for line and load connections.
Special CO/ALR solderless connectors must be used if the thermostat will
be connected to aluminium wires.
• The thermostat wires are not polarized; either wire can be connected to the
load or to the power supply.
• Keep the air vents at the top and bottom of the thermostat clean and free
from obstructions.