EH222 and Condensing Unit Remote Low Side Cuber User Manual Introduction: This manual covers the assembly, installation, start up, operation and maintenance of the 800 and 1000 remote low side cuber systems. Contents Configuration ..........Page 3 Specifications and Location Information .
Scotsman. Scotsman reserves the right to make design changes and/or improvements at any time. Specifications and design are subject to change without notice.
EH222 and Condensing Unit Remote Low Side Cuber User Manual Specifications and Location Information Model Electrical Minimum Maximum System Charge, Cabinet Size* Unit Weight volts/Hz/phase Circuit Fuse Size oz of R-404A w” x d” x h” (lb) Ampacity EH222SL-1C 115/60/1 1.13 shipped w/none 22 x 16.5 x 29...
EH222 and Condensing Unit Remote Low Side Cuber User Manual Cabinet Drawings, Condensing Unit TOP VIEW 992.81 39.09 814.22 32.06 SIDE VIEW LINE SET AND ELECTRICAL ATTACHMENT SIDE 750.06 29.53 32.05 330.86 1.26 13.03 FRONT VIEW TYP. 887.73 34.95 .88" ELECTRICAL INLET 3/4"...
• Scotsman ID150: KBT40 There are two ways water can contain impurities: • Scotsman ID200 or ID250: KBT41 in suspension or in solution. Suspended solids can be filtered out of the water. In solution or dissolved Bin Adapter Kits: solids must be diluted or treated. Water filters are •...
The remote tubing connections are at the top of the machine, and connections should not be made until In 2013 Scotsman made a change to the Eclipse the machine is nearly in its final installed position. tubing kits: The 115/60 Hz ice making section is cord connected •...
EH222 and Condensing Unit Remote Low Side Cuber User Manual Place Remote System Roof preparation Roof Pipe Curb or Pitch Pocket: Most installations of this system will place the To avoid potential kinking of the refrigeration tubing, condensing unit on the roof of a building. The roof avoid small, tight radius types of covers on pitch must be physically able to accept the load of the pockets.
EH222 and Condensing Unit Remote Low Side Cuber User Manual Tubing The line set must be routed between the condensing unit and the ice maker’s location. During the transition from quick connects to braze connections, the ice maker, condensing unit and line set may or may not have quick connects, use this chart as a guideline for the proper action based on what is available at the site.
NOT have gasket tape install tape such as supply and a gravity drain. Scotsman part number 19-0503-04. The adapter to Determine how the drain will be connected to the ice ice head base MUST be sealed with gasket tape or making section.
EH222 and Condensing Unit Remote Low Side Cuber User Manual Drain Connections Right Draining: Left Draining: Rotate elbow to the other direction. 1. Connect ¾” PVC to the female PVC fitting. Connect ¾” PVC to the PVC fitting. If copper is required by code, remove the PVC Back Draining: Rotate elbow to face the back or connector and install a ¾”...
EH222 and Condensing Unit Remote Low Side Cuber User Manual Water Supply: A 3/8" flare nut on tubing is located at the top panel, near the refrigeration tubing. Inside the hardware bag, inside the cabinet, a 3/8" inch double male flare adapter (flare union) is supplied.
EH222 and Condensing Unit Remote Low Side Cuber User Manual Electrical: Condensing Unit Head Route interconnecting control wire through proper Plug head’s power cord into a nearby 115 volt hole end of condensing unit and plug into the electrical outlet. connection on the control box.
EH222 and Condensing Unit Remote Low Side Cuber User Manual Connect Refrigeration Requires brazing, steps must be performed by an At Head EPA certified type II or higher technician. 1. With nitrogen flowing from condensing unit, braze At Head: the liquid, vapor and suction line connections. 1.
EH222 and Condensing Unit Remote Low Side Cuber User Manual Complete the Installation After the utilities and refrigeration connections have Note: The refrigerant lines above the machine must been made, secure the unit to the dispenser or bin be able to move freely while the machine is being top.
EH222 and Condensing Unit Remote Low Side Cuber User Manual Reference for Start Up: Controller Operation The controller has four indicator lights, a code display, Component indicator lights four push buttons, and eleven component indicator lights. • Fan - not used on this model •...
7. Go to the condensing unit and confirm that the 11. Fill out and mail the warranty registration form or compressor and fan motor are operating. Warm register it on line at www.scotsman-ice.com. air will be discharged from the condenser. Observe the Ready for Harvest indicator light. It may blink early in the cycle, that is normal.
EH222 and Condensing Unit Remote Low Side Cuber User Manual Ice Thickness and Water Purge Adjustment Bridge Thickness - For the Service Tech Only 1/8 to 3/16” 1. Push and hold Off till the machine stops. Bridge 2. Remove evaporator cover. 3.
EH222 and Condensing Unit Remote Low Side Cuber User Manual Adjustable Ice Level Control There is an adjustment post and an additional indicator light to the right of the four indicator lights. The cuber drops ice in large sections. That ice will The ultrasonic ice level control allows the user to break up into random parts as it falls into the bin, but control the point that the ice machine will stop making...
Go onto the next step when the purge valve light goes out. 12. Remove curtain from unit. 6. Pour 12 ounces of Scotsman Clear 1 nickel safe 13. Locate ice thickness sensor. Squeeze mounting scale remover into the reservoir. legs together to release sensor.
Page 23
If the coils have become coated with grease, a coil Scotsman also has a sanitizer, contact your local cleaner will have to be used to wash the coils. Scotsman Distributor for information.
EH222 and Condensing Unit Remote Low Side Cuber User Manual Operational Characteristics 800 lb system Cycle Times @ Condenser Temp/Cabinet Temp/Water Temp in degrees F. 70/70/50 90/90/70 120/110/100 Freeze 10 to 12 minutes 13 to 15 minutes 19 to 21 minutes Harvest 1 to 1.5 minutes 1 to 1.5 minutes...
EH222 and Condensing Unit Remote Low Side Cuber User Manual What to do before calling for service: Reasons the machine might shut itself off: • Lack of water. • Freeze cycle takes too long. • Harvest cycle takes too long. •...
EH222 and Condensing Unit Remote Low Side Cuber User Manual EH222 Schematic Diagram LINE HARVEST TRANSFORMER ASSIST SOLENOID HOT GAS VALVE RELAY CONTACTOR RELAY WATER VALVE ELECTRONIC CONTROL WATER SUMP LEVEL TEMP. SENSOR CURTAIN SWITCH 2 THICKNESS PROBE DISCHARGE CURTAIN TEMP.
EH222 and Condensing Unit Remote Low Side Cuber User Manual EH222 Wiring Diagram USE COPPER CONDUCTORS ONLY 1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL 17-3111-01 CODE AND ALL STATE AND LOCAL CODES. BN/W WATER HARV ASSIST...