Controller Information

Machine Indicator Lights
Power
Status
Water
Clean
Code Display
Main codes - automatically displayed
Freeze Cycle
F
flashes Freeze Cycle is Pending
F
Harvest Cycle
H
flashes Manual Harvest
H
Bin is Full
b
Clean Cycle
C
Board Locked
L
Test Mode
d
Off
O
Self Test Failed
E
flashes Max Freeze - Retrying
1
Max Freeze Time Shut Down
1
flashes Max Harvest - Retrying
2
Max Harvest Time Shut Down
2
Slow Water Fill
3
High Discharge Temp
4
Sump Temp Sensor Failure
5
Discharge Temp Sensor Failure
7
flashes Short Freeze - Retrying
8
Short Freeze - Thin ice
8
Settings - requires push button sequence for access
Water Purge Settings Available - A is factory default
A, 1, 2, 3, 4, 5
De-scale Interval Settings Available - 6 is factory default
6, 5, 3, 0
Diagnostic Code (numbers) Notes:
1. Retrying means the controller will try at least one
more cycle before a manual reset is required.
2. A non-blinking code number means the retry
periods have not been successful.
3. Codes may be recalled for review. Recalled codes
that blink indicate that the unit recovered from that
code. If it failed to recover, the code will be on
steady.