Epec 6200 Manual
Hide thumbs Also See for 6200:
Table of Contents

Advertisement

Quick Links

Epec 6200 Control Unit
Technical Document
Functional Versions
6200-222
6200-223
6200-268
6200-269
Document version history
Date
Notes
31.03.2022
Added: Functional Version 6200-222
23.11.2021
Preliminary Release
Added: Industry Canada Compliance Statement
30.03.2020
First released version
MAN000719
PUBLIC
© Epec Oy

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Epec 6200

  • Page 1 Epec 6200 Control Unit Technical Document MAN000719 PUBLIC Functional Versions 6200-222 6200-223 6200-268 6200-269 Document version history Date Notes 31.03.2022 Added: Functional Version 6200-222 23.11.2021 Preliminary Release Added: Industry Canada Compliance Statement 30.03.2020 First released version © Epec Oy...
  • Page 2: Table Of Contents

    13.1.1 Temperature Monitoring ..............38 13.1.2 Supply Voltage Monitoring ............... 38 13.2 LED Indicator .................... 39 13.3 + 5 V REF Diagnostics ................41 13.3.1 OVERLOAD ..................41 Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194...
  • Page 3 15.6 Accessories and Ordering Codes ............... 72 15.6.1 Related products ................72 15.6.2 AMPSEAL Connectors ............... 74 15.6.3 AMPSEAL cable dimensions .............. 74 GLOSSARY ........................75 Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194...
  • Page 4: Preface

    The (electrical) warning icon indicates a hazard which could cause an electrical danger and/or a personal injury. The following symbols may be used on Epec's product labels: Caution, surface may be hot. CE compatibility This symbol indicates that the product complies with the requirements set in the CE Standard.
  • Page 5: Basic Skills Required

    The system should be designed and constructed according to the Epec general mounting and cabling instruction document. Epec Oy reserves a right to improve its products without a further notice. Warranty Information concerning the warranty of this product can be found from Epec General Sales and Warranty Terms.
  • Page 6: Limited Liability

    (placed on the upper right part of the PCB). When recycling the product, make sure that the battery is removed from the PCB and recycled separately. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address...
  • Page 7: Product Overview

    Epec 6200 RAU has multiple use cases such as data collection, communication gateway, remote access or edge computing. Epec 6200 RAU is fully compatible with the existing Epec control units and supports Epec GlobE remote management platform, Epec GatE secure access solution, CODESYS 3.5 WebVisu functionality, Epec...
  • Page 8: Functional Versions

    USB (M12) USB (M12) Connectors 1xM12 1xM12 3xM12 3xM12 2xSMA 4xSMA 4xSMA 4xSMA Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki FIN-60101 Seinäjoki, Finland...
  • Page 9 -30... +60 °C Temperature range -22...+140 °F CODESYS version Supported CAN CANopen higher layer SAE J1939 protocols Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki...
  • Page 10: Technical Data

    7.16 in x 6.02 in x 2.16in Weight 1,2 kg 2.6 lbs Protection class IP 67 Case material Aluminum Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi...
  • Page 11 (sourcing, up to 1 A) Inputs 2x DI (pull-down to GND) 1x AI/DI (0-5 V / 0-22 mA and pull-up selection by application) Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi...
  • Page 12: Connectors And Pin Assignments

    Connector type GSM/UMTS/LTE RP-SMA FEM WLAN SMA FEM GPS/GLONASS SMA FEM LTE Diversity RP-SMA FEM Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki...
  • Page 13 DIGITAL_OUTPUT_2 DO/DI PWR_GND PWR_IN *Hardware specific X2, mini-B-USB connector Picture Signal +5 V (max 500 mA) Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki...
  • Page 14 CAN5 H CAN5 L X6, M12 connector (5 pin MALE) Picture Signal CAN shield CAN6 H CAN6 L Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi...
  • Page 15: Do/Di

    It’s highly recommended to use closed loop connections when the output pin is used as an input. By keeping this simple principle in your mind you will avoid many unknown problems later on Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address...
  • Page 16 The switching does not affect the application software. Note 7: Overload conditions Note 8: Includes hysteresis. The input state is maintained until the second voltage limit is exceeded. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194...
  • Page 17: Functional Block Diagram

    6200 Technical Manual Page 17 MAN000719 PUBLIC Functional block diagram Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki FIN-60101 Seinäjoki, Finland...
  • Page 18: Ai/Di

    The protection circuit can be bypassed (the switch will reconnect the measurement circuit) momentarily with a reset signal (DEV_DSC_OVP_RESET_X1_17). The signal is edge activated and the bypass time is fixed. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone...
  • Page 19 Note 4: HW multiplies the measurement by 10/11. The effect is compensated in 6107Int.library (the measurement is multiplied by 11/10), so the measurement is automatically accurate when using Epec programming libraries. For more information about conversions, refer to Epec Programming and Libraries manual.
  • Page 20: Functional Block Diagram

    6200 Technical Manual Page 20 MAN000719 PUBLIC Functional block diagram Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki FIN-60101 Seinäjoki, Finland...
  • Page 21 Note 1: Exceeding the max values might cause damage to input. Note 2: Overload conditions. Note 3: Includes hysteresis. The input state is maintained until the second voltage limit is exceeded Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone...
  • Page 22: Functional Block Diagram

    6200 Technical Manual Page 22 MAN000719 PUBLIC Functional block diagram Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki FIN-60101 Seinäjoki, Finland...
  • Page 23: Accelerometer (Option)

    ±2 g Measurement range, Z-axis: ±2 g Related programming Accelerometer.lib (For more information, see Epec libraries: Programming and Libraries manual) Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi...
  • Page 24: 10 +5 V Ref

    Note 4: The measurement is scaled down before the conversion. The effect is compensated in Epec software libraries. For more information, see Epec Programming and Libraries manual. Epec Oy reserves all rights for improvements without prior notice...
  • Page 25: Functional Block Diagram

    6200 Technical Manual Page 25 MAN000719 PUBLIC 10.3 Functional block diagram Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki FIN-60101 Seinäjoki, Finland...
  • Page 26: Power Supply

    Always use an external fuse to protect the unit. The fuse is needed for reverse voltage and overload protection. For more information, see section Power Supply Cabling. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address...
  • Page 27 Note 2: Limited functionality when the voltage is higher than the nominal. If the voltage is less than 7,7 V, the unit is in non-operational state. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address...
  • Page 28: Interfaces

    The CAN2 communication pins are located in the control unit's AMP23 (X1) connector as follows: Picture Signal CAN2 L CAN2 H GND (DATA GROUND) GND (DATA GROUND) Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi...
  • Page 29 The CAN6 communication pins are located in the control unit's M12 (X6) connector as follows: Picture Signal CAN shield CAN6 H CAN6 L Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi...
  • Page 30: Rs-232

    Picture (AMP23 male Signal connector, front) TXD, transmit data RXD, receive data GND (DATA GROUND) GND (DATA GROUND) Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi...
  • Page 31: Usb

    USB ports provide a flexible way to attach peripheral devices. However, it should be noted that the core of the unit is based on embedded processor architecture. Therefore, it is strongly recommended to consult Epec to assess the compatibility with the product when selecting a new USB device.
  • Page 32: Ethernet

    6200 Technical Manual Page 32 MAN000719 PUBLIC 12.4 Ethernet Firewall can be activated for Ethernet, for more information refer to Epec Programming and Libraries manual. Supported Ethernet amount: max 2 Bus speed: Maximum 10/100 Mbps Cabling instructions: See section Ethernet Cabling...
  • Page 33: Cellular Gsm/Umts/Lte

    (For more information, see Epec Programming and Libraries manual) *) Recommended to use Plantec Planar Combination Antenna K98LLVR (for using other antenna types, additional testing is required) Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone...
  • Page 34 6200 Technical Manual Page 34 MAN000719 PUBLIC Correct SIM card position and antenna connector location: Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki...
  • Page 35: Wlan

    *) Recommended to use Plantec Planar WLAN Antenna M70XFR (Antenna Gain -3.0 dBi) (for using other antenna types, additional testing is required) Correct antenna connector location: Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address...
  • Page 36: Gps/Glonass

    (For more information, see Epec Programming and Libraries manual) *) Recommended to use Plantec Planar Combination Antenna K98LLVR (for using other antenna types, additional testing is required) Antenna connector location: Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194...
  • Page 37: Lte Diversity

    See section Accessories and Ordering Codes * *) Recommended to use Plantec Planar Combination Antenna K98LLVR (for using other antenna types, additional testing is required) The correct antenna connector location: Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone...
  • Page 38: Internal Diagnostics

    Diagnostics High Unit Recommended supply voltage warning level For additional electrical characteristics refer to section Power Supply. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki...
  • Page 39: Led Indicator

    Three LEDs are situated on the connector side of the unit. LED2 and LED3 are user programmable; refer to Epec Programming and Libraries Manual for more information. LED1 is described in this chapter. The LED1 indicator is the left LED, according to the...
  • Page 40 Red LED Application exception, constantly Application for example, division by Exception zero. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki...
  • Page 41: Ref Diagnostics

    The unit can handle short term errors, but long term (e.g. several hours) exposures should be avoided with application/system design. Long term exposure to overvoltage or overload can cause permanent damage to the unit. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone...
  • Page 42: Approvals And Safety

    MAN000719 PUBLIC APPROVALS AND SAFETY 14.1 EMC Tests Epec 6200 units are tested according to EMC tests that are described in this section. The following tables provide a summary of performed EMC tests: Measurement / test Reference standard Conducted Emissions from the Mains Cable...
  • Page 43: Rf Tests

    MAN000719 PUBLIC 14.2 RF Tests Epec 6000 series units comply with Radio Equipment Directive (2014/53/EU). Epec 6200 units are tested according to following RF requirements: Measurement / test Reference standard Radiated spurious emissions — MS allocated EN 301 511 V12.5.1...
  • Page 44 7637-2: 2004/Amd.1:2008 Port Limit level (V) 12 V DC input -100 +150 24 V DC input - 450 Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi...
  • Page 45 +290 V, 10/90 ms, 60 min 100 ms -12 V, 20 s -5 V, 10 pulses 350 ms, R 1 Ω, +123 V, 1 pulse Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194...
  • Page 46 Class E: One or more functions of a device/system do not perform as designed during exposure and cannot be returned to operation without repairing the device/system. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address...
  • Page 47 (MHz) Modulation 80-1000 10 V/m AM 80% 1 kHz, 1000- 3 V/m Dwell time 3s 6000 Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki...
  • Page 48 • Performance criterion A Discharge mode Test level Vertical/Horizontal 30 A/m 50/60 Hz, 5 min Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki...
  • Page 49 Performance criterion A: The EUT shall continue to operate as intended during and after the test. No degradation of performance is allowed. Performance criterion B: Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone...
  • Page 50 The EUT shall continue to operate as intended after the test. However, moderate degradation of performance is allowed. No change of actual operating state or loss of memory functions is allowed. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address...
  • Page 51: Environmental Tests

    6200 Technical Manual Page 51 MAN000719 PUBLIC 14.3 Environmental Tests The following environmental tests have been performed to Epec 6200 units: Temperature Duration/ Test Temperature Exposure Remarks time Cold -30 °C 16 h • 1 °C/min IEC 60068-2-1 (2007- 03),Test Ad Dry heat +60 °C...
  • Page 52: Simplified Eu Declaration Of Conformity

    Page 52 MAN000719 PUBLIC 14.4 Simplified EU Declaration of Conformity Epec Oy hereby declares that this device is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://extranet.epec.fi/Public/Declarations/Epec6200_4G_DeclarationOfConformity.pdf Frequency, mode and maximum transmitted power 14.4.1...
  • Page 53: Industry Canada Compliance Statement

    Toute modification non approuvée explicitement par le fournisseur de licence de l’appareil peut entraîner l’annulation du droit de l’utilisateur à utiliser l’appareil. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address...
  • Page 54: Information

    (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address...
  • Page 55: Mechanics And Cabling

    Make sure that all the unused connectors are sealed properly using the provided covers (sealing cap protection class is IP67). Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address...
  • Page 56 Mounting position must be horizontal or vertical to allow water, etc. flowing away from connectors, see the figures below. Do not mount the unit in a position where the connector side is facing upwards: Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address...
  • Page 57: Plugging And Unplugging The Cables/Connectors

    MAN000719 PUBLIC 15.3 Plugging and unplugging the cables/connectors Epec control units use heavy duty gold plated, locked and sealed AMPSEAL connectors. The following figure shows an example of an AMPSEAL connector: • Gold plated AMPSEAL connectors pack a current of 15 amperes per contact and tolerate operating temperature range.
  • Page 58 Refer to AMP Application Specification 114-16016 for more detailed information on connectors and cable recommendations. Ordering codes for the AMPSEAL connectors, crimps and tools are listed in Section Accessories and Ordering Codes. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194...
  • Page 59: Cabling

    The control units are connected with each other using standardized CAN bus. • The idea of the Epec embedded control system, is that all the control units are installed close to sensors, encoders and other equipment connected to them. •...
  • Page 60 The maximum length of the bus depends on the bus speed. For more information about the bus speeds, see the table below / refer to CiA DS-102 standard. Epec Oy reserves all rights for improvements without prior notice Epec Oy...
  • Page 61: Can Bus Cabling

    • The shield grounding must be done only in one end of the cable Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone...
  • Page 62 Connection example when there is a GND pin (X1.22) available in the control unit: Connection example when there is not a GND pin available in the control unit: Epec Oy reserves all rights for improvements without prior notice Epec Oy...
  • Page 63 PUBLIC 15.4.2.3 CAN cabling for system developers The following figure describes cabling for CAN communication between Epec control units and a PC. Ordering codes for the needed hardware are included in the figure. An external termination resistor (120 Ω) has to be connected at both ends between CAN H and CAN L.
  • Page 64: I/O Cabling

    Using shielded cable is recommended also in joystick connections. The following figure describes four different ways to connect closed circuit loop through the control unit: Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone...
  • Page 65: Ethernet Cabling

    In order that the electromagnetic interference (EMI) would not affect the data transfer, the installation of the cable should be done as close as possible to the body of the machine. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address...
  • Page 66 (rxd-) 3 (txd2-) Orange (txd1-) (txd-) Blue White/ blue White/ brown Brown Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki FIN-60101 Seinäjoki, Finland...
  • Page 67 Ordering codes for the needed hardware are included in the figure. To check 6000 series unit's IP addresses, use ApplicationLoader (device software). For more information, see Epec Programming & Libraries Manual: Programming > Programming 6000 Series Units > Configuring Ethernet and DNS Settings (available from Epec's Extranet).
  • Page 68: Rs-232 Cabling

    GND = Signal Ground • The maximum length of the cable is 3 m • The following picture is an example of a connection between Epec 6000 series unit and PC with 3-wire connection. RS-232 cabling connection: AMP23 female connector...
  • Page 69: Power Supply Cabling

    No external power (or ground) connections are allowed. • The nominal operating voltage for Epec control units is 12 and 24 VDC. The full operating range is 8,4…36 VDC • See section...
  • Page 70: Antenna Installation

    7) communication, a minimum distance of 70 cm should be maintained between LTE and WLAN antennas in all installations. Due to potential coexistence interference in wireless communication, LTE/WLAN combination antenna is not recommended. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone...
  • Page 71: Welding

    Welding grounding should be connected close to the welding point to avoid long distance high current flow through machine frame. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address...
  • Page 72: Accessories And Ordering Codes

    MAN000614 (M12 USB mini-B - USB A male) 2 m Ethernet KW0209 MAN000585 Cable M12/M12 Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki...
  • Page 73 KX0423 cap for male connector (IP67) M12 sealing X0058261 cap for female connector (IP67) Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone Internet Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 www.epec.fi FIN-60320 Seinäjoki FIN-60101 Seinäjoki, Finland...
  • Page 74: Ampseal Connectors

    Card AMPSEAL Connectors 15.6.2 Epec uses gold plated, locked and sealed AMPSEAL heavy duty connectors for all Epec CAN Control Unit Family products to ensure endurance under extreme conditions. • All connectors are mechanically keyed to mate only with identical colors...
  • Page 75: Glossary

    ECC: Error-correcting code memory Firmware: Firmware is the device software programmed into memory contained in the hardware. Epec firmware can be updated by the customer, Epec firmware does not include boot loader. GFG: Glass-Film-Glass. A touchscreen panel with a robust glass surface designed for harsh environmental conditions.
  • Page 76 TFT: Thin-Film-Transistor display. A display that uses thin-film transistor technology to improve image qualities such as addressability and contrast. Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone...
  • Page 77 UVP: Undervoltage Protection WVGA: Wide Video Graphics Array. A display resolution with the same 480 pixel height as VGA but wider, such as 800×480 (5:3). Epec Oy reserves all rights for improvements without prior notice Epec Oy Postal address Phone...

Table of Contents