Air Delivery - Cfm - Carrier N96MSN Installation, Start-Up, Operating And Service And Maintenance Instructions

Single-stage, high efficiency, 4-way multipoise 35-in. (889 mm), condensing gas furnace
Table of Contents

Advertisement

N96MSN: Installation, Start-up, Operating and Service and Maintenance Instructions
Example 2
A direct-vent 60,000 BTUh furnace installed at 2100 ft. (640M). Venting system includes FOR EACH PIPE:
100 feet (30 M) of vent pipe, 95 feet (29 M) of combustion air inlet pipe, (3) 90º long-radius elbows, and a polypropylene concentric vent kit. Also
includes 20 feet (6.1 M) of flexible polypropylene vent pipe, included within the 100 feet (30 M) of vent pipe.
VERIFY FROM POLYPROPYLENE VENT MANUFACTURER'S INSTRUCTIONS for the multiplier correction for flexible vent pipe.
Can this application use 60mm o.d. (2") polypropylene vent piping? If not, what size piping can be used?
Measure the required linear length of RIGID air inlet and vent pipe; insert the longest of
the two here: 100 ft. Of rigid pipe - 20 ft. Of flexible pipe
Add equiv length of (3) 90º long-radius elbows (use the
highest number of elbows for either the vent or inlet pipe)
Add equiv length of 45º long-radius elbows
(use the highest number of elbows for either the vent or
inlet pipe)
Add equiv length of factory concentric vent term
Add correction for flexible vent pipe, if any
* VERIFY FROM VENT MANUFACTURER'S INSTRUCTIONS; For example only, assume 1 meter of
flexible 60mm (2") or 80mm (3") polypropylene pipe equals 2.0 meters (6.5 ft.) of PVC/ABS pipe.
Total Equivalent Vent Length (TEVL)
Maximum Equivalent Vent Length (MEVL)
Is TEVL less than MEVL?
Maximum Equivalent Vent Length (MEVL)
Is TEVL less than MEVL?

AIR DELIVERY - CFM

Airflow
Unit Size
Setting
1
Cont. Fan
2
3
4
5
6
7
8
9
0261410
10
11
12
13
14
15
16
17
18
1
Cont. Fan
2
3
4
5
6
7
8
9
0401410
10
11
12
13
14
15
16
17
18
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
3
0
9
2*
Table 18 – Air Delivery - CFM (with filter)
Default
Setting
0.1
0.2
470
395
510
445
535
470
560
495
595
535
Heat
620
560
665
605
705
650
745
695
785
735
820
775
855
810
890
845
945
905
980
940
1025
985
1065
1030
Cooling
1115
1080
390
335
405
355
455
405
485
440
530
485
565
525
600
560
645
605
Heat
705
665
720
685
760
730
820
785
865
835
910
885
965
935
1005
975
1055
1025
Cooling
1100
1075
=
80 ft.(24 M)
x
5 ft.(1.5 M)
=
15 ft.(4.6 M)
x
=
0 ft.(0 M)
x
3.3 ft(0.9 M)
=
30 ft.(9 M)
x
20 ft.(6.1 M)
=
40 ft.(12.2 M)
165 ft.(50 M) Add all of the above lines
95 ft.(29 M)
185 ft.(57 M) For 3" pipe from
External Static Pressure (IN.W.C.)
0.3
0.4
0.5
320
250
175
370
305
240
400
335
275
430
365
310
470
405
350
500
435
375
550
490
430
600
540
480
645
590
535
685
635
585
730
680
630
765
720
675
800
755
710
860
820
775
900
860
820
950
910
870
995
955
920
1045
1010
970
275
215
155
300
240
185
355
305
250
390
345
295
440
395
350
485
440
400
520
480
440
570
530
495
630
595
560
650
615
580
695
660
630
755
725
690
805
775
745
855
825
800
905
880
855
950
925
900
1000
975
950
1050
1025
1000
48
Use length of the longer of the vent
or air inlet piping system
Example from polypropylene vent
manufacturer's instructions, Verify from
vent manufacturer's instructions.
For 2" pipe from
Table 14
Therefore, 60mm (2") pipe may NOT be
NO
used; try 80mm (3")
Table 14
YES
Therefore, 80mm (3") pipe MAY be used
0.6
0.7
0.8
-
-
-
165
-
-
200
130
-
245
170
-
295
225
155
320
265
195
380
330
270
430
380
335
480
435
385
530
480
435
575
525
485
620
570
525
665
615
570
735
690
640
780
735
690
830
795
750
880
845
805
935
900
865
-
-
-
125
-
-
200
140
-
245
190
140
300
255
205
355
310
270
400
360
320
455
415
375
525
490
455
545
515
480
595
560
530
660
630
600
715
690
660
770
740
710
825
800
770
870
845
820
925
900
875
980
955
930
0.9
1
-
-
-
-
-
-
-
-
-
-
130
-
205
140
280
215
340
285
390
350
440
400
485
445
530
490
595
560
645
605
710
665
760
720
825
785
-
-
-
-
-
-
-
-
155
-
220
170
275
230
335
300
415
380
440
405
495
460
570
535
630
600
685
655
745
715
795
765
850
825
905
880

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents