Connecting Power And Aligning Photo Eye Safety System - beamUP BU250 Product Manual

Table of Contents

Advertisement

CONNECTING POWER AND ALIGNING PHOTO EYE SAFETY SYSTEM

NOTICE:
The garage door opener cannot be programmed
and will not close the door until photo eye safety
system are installed and aligned.
WARNING
To prevent SERIOUS INJURY or DEATH from
electrocution or fire:
• Power MUST be DISCONNECTED BEFORE
proceeding with permanent wiring procedures.
• Garage door opener installation and wiring MUST
be in compliance with all local electrical and
building codes. Make sure the opener is ALWAYS
grounded.
• NEVER use an extension cord, 2-wire adapter or
modify the power plug in any way to make it fit the
outlet.
To prevent SERIOUS INJURY or DEATH from a closing
garage door:
• The photo eye safety system MUST be installed
BEFORE connecting power.
• The photo eye safety system MUST be properly
connected and aligned BEFORE operating the
opener.
18
beamlabs.io
1-800-436-9186
* DO NOT OPERATE OPENER AT THIS TIME *
Plug power head into a grounded outlet ONLY. If there
is no grounded outlet present, call a qualified electrician
to replace the outlet. Use of a surge protector is highly
recommended.
Right
Wrong
When the photo eye safety system is properly
aligned green LED (emitter) will emit a steady green
light and the red LED (sensor) will emit a steady red
light. The path of the invisible light beam MUST NOT
be obstructed. No part of the garage door or any
hardware should interfere or block either sensor.
For Permanent Wiring ONLY
Conduit with wire
Line (Black)
Neutral (White)
White
(From Transformer)
Green LED (emitter) will flash until it is aligned with
red LED (sensor). Red LED will not illuminate until it
is aligned with green LED.
Emitter
Green LED ON
Steady Red &
The emitter generates the invisible light beam, and
Invisible
the sensor receives the invisible light beam.
Light Beam
Ground (Green/Yellow)
Ground Screw (Green)
Wire nut
Brown
Black
Sensor
Red LED ON
Aligned
Green LED