Connecting Photo Eye Safety System - beamUP BU250 Product Manual

Table of Contents

Advertisement

CONNECTING PHOTO EYE SAFETY SYSTEM

Look in the box for:
Photo Eyes
Insulated Staples
WARNING
To prevent SERIOUS INJURY or DEATH from
electrocution:
• Power MUST NOT be connected until instructed.
• The garage door opener will not operate until the
photo eye safety system is properly connected and
aligned.
• Install the photo eye safety system NO higher than
6 inches (15 cm) above the floor.
• No part of garage door or other objects should
obstruct the photo eye safety system during door-
closing.
Mount photo eyes using #12 x 1-1/4" screws provided.
4 x Screws
#12 x 1-1/4"
* VERY IMPORTANT! *
Strip 7/16 inch (1 cm) of insulation
from the end of the wire.
Each pair of terminals MUST be
connected with one white wire and
one striped wire (non-polarized) from
the SAME photo eye.
Photos eyes
Alternative mounting location:
should be no
Door track mounting
more than 6
inches (15.2 cm)
above the floor.
Floor mounting
(concrete anchors
not provided)
Cut and discard excess wire. Use small flat head screwdriver to
push in grey tab on the terminal block located on the rear panel
of the power head. Insert 1/2 inch (1.2 cm) of the wire into the
terminal while pushing in the tab.
7/16 inch
(1 cm)
Run wire to power head. Use insulated staples
to secure photo eye wires to wall and ceiling.
Take care not to puncture the wires while
securing staples.
beamlabs.io
1-800-436-9186
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bu850