Elation PIXEL NET 4 User Manual page 12

Table of Contents

Advertisement

POWER AND DATA CONNECTIONS
Power and data are supplied to the PIXEL BARS via the input and output RJ45
connectors and CAT5e Ethernet cable using a daisy chaining method. The following
diagram indicates the pin assignment of the RJ45 connector.
Connect the output of the PIXEL NET 4
BAR
Connect the output of the first fixture in the chain to the input of the next
fixture. Always connect one output with the input of the next fixture until all fixtures
are connected. The following diagram provides an example of power and data
connections.
PIXEL NET 4
First PIXEL BAR
POWER LINKING
Maximum number of bars that can be linked to a single PIXEL NET 4
PIXEL BAR12
- Max 52 bars (13 per each output port)
PIXEL BAR20
- Max 32 bars (8 per each output port)
- Max 16 bars (4 per each output port)
PIXEL BAR40
*CAT5e cable length from PIXEL NET 4 port to last PIXEL BAR unit = 98.4 ft (30m) MAX
w w w . e l a t i o n l i g h t i n g . c o m
device directly to the input of the first PIXEL
12
Last PIXEL
BAR*
*SEE NOTE BELOW