Safety Interlock Continuity Test - Daewoo KOG-36A5 Service Manual

Hide thumbs Also See for KOG-36A5:
Table of Contents

Advertisement

SAFETY INTERLOCK CONTINUITY TEST

¥ Disconnect the oven from the power supply.
¥ You can test continuity of safety interlocks and monitor switch by using switch tester or ohmmeter.
¥ The switch operation is checked by the lamp on/off of resistance zero/unlimited.
¥ The sequence of check is interlock monitor switch; primary and secondary interlock switches check.
¥ Make circuits like Fig. a, Fig. b, Fig. c for tests.
1) In case of interlock monitor check.
(Lamp on or zero resistance)
Condition: 1) Door is opened.
2) Common terminal of the monitor
switch disconnected.
3) In case of secondary interlock switch.
(Lamp on or zero resistance)
Condition : 1) Door is closed.
(ohmmeter)
– Fig. a –
(ohmmeter)
– Fig. c –
2) In case of primary interlock check.
(Lamp on or zero resistance)
Condition: 1) Door is closed.
ƒN(Schematic diagram of S/W tester)
26
(ohmmeter)
– Fig. b –