HOOD INSTALLATION, MAINTENENCE AND USAGE
LA 90 Celux BR SS
LA 90 Celux BR WHT
Please register your warranty at
www.luxairhoods.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LA 90 Celux BR SS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Luxair LA 90 Celux BR SS

  • Page 1 HOOD INSTALLATION, MAINTENENCE AND USAGE LA 90 Celux BR SS LA 90 Celux BR WHT Please register your warranty at www.luxairhoods.com...
  • Page 2 Must be installed on minimum 6" round or rectangular equivalent ducting*...
  • Page 3 Must be installed on minimum 6" round or rectangular equivalent ducting*...
  • Page 4 Must be installed on minimum 6" round or rectangular equivalent ducting*...
  • Page 5 Closely follow the instructions set out in this manual. All re- sponsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined. The extractor hood has been designed exclusively for domestic use. The hood can look different to that illustrated in the drawings in this booklet.
  • Page 6 by a person responsible for their safety. This appliance is designed to be operated by adults, children should be monitored to ensure that they do not play with the appliance. This appliance is designed to be operated by adults. Children should not be allowed to tamper with the controls or play with the appliance.
  • Page 7 instructions provided in this manual). Failure to follow the instructions provided in this user guide regarding the cleaning of the hood and filters will lead to the risk of fires. Do not use or leave the hood without the lamp correctly mounted due to the possible risk of electric shocks.
  • Page 8: Ducting Version

    Ducting version In this case the fumes are conveyed outside of the building by means of a special pipe connected with the connection ring located on top of the hood. Attention! The exhausting pipe is not supplied and must be purchased apart. Diameter of the exhausting pipe must be equal to that of the connection ring.
  • Page 9: Electrical Connection

    hob and the lowest part of the range hood must be not less than 50cm from electric cookers and 65cm from gas or mixed cookers. If the instructions for installation for the gas hob specify a greater distance, this must be adhered to.
  • Page 10: Operation

    Operation Use the high suction speed in cases of concentrated kitchen vapours. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cooking. –...
  • Page 11: Grease Filter

    Cleaning The cooker hood should be cleaned regularly (at least with the same frequency with which you carry out maintenance of the fat filters) internally and externally. Clean using the cloth dampened with neutral liquid detergent. Do not use abrasive products. DO NOT USE ALCOHOL! WARNING: Failure to carry out the basic cleaning recommendations of the cooker hood and replacement of the filters may cause fire risks.