Open the supply shut-off valve and check all connections
for leakage. If the connections have been properly
assembled, a slight retightening of the nuts should stop
any leakage.
If the toilet is leaking between the tank and the bowl,
carefully retighten the three brass nuts evenly.
Periodically check all the bowl and tank connections for
leakage for several days following installation.
Install the toilet seat according to the seat manufacturer's
installation instructions.
FILL FLOAT WITH BALLAST
Hold the float under water for a few seconds to fill it with
water ballast. Adjust the float by sliding it up or down on
the float rod until the water level is at the marked water
line.
Test flush the toilet.
Periodically check all connections for leaks for several
days following installation.
WARNING: Risk of personal injury or property
damage. Do not flush the toilet with the float valve
cap removed. Pressurized water will spray upward,
and may cause injury or water damage.
Set the tank cover in place on the tank.
BA
113786-2-
(9521)
Float Valve Cap
Float
5
Fig. #9