Technical Description Of The Burner; Technical Data; Burner Description - Riello RDB1 50 Installation, Use And Maintenance Instructions

Kerosene burners, one stage operation
Table of Contents

Advertisement

4

Technical description of the burner

4.1

Technical data

Type
Output - Thermal power
(with air at 20 °C)
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power 0.115 kW
 Gas oil is not permitted on low level discharge of flue gas products.
4.2

Burner description

3
8
D6310
1
Pump
2
Control box
3
Reset button with lock-out lamp
4
Flange with insulating gasket
5
Air damper adjustment screw
6
Pump pressure adjustment screw
7
Pressure gauge port
8
Photoresistance
9
Blast tube
3121
Technical description of the burner
501 T1K
1.4 - 2.2 kg/h
16.8 - 26.3 kW
Kerosene, viscosity 1.6 – 6 mm
Gas oil, viscosity 4 – 6 mm
Single phase, ~ 50Hz 230 V ± 30%
Run current 0.7 A – 2700 rpm – 283 rad/s
4.5 F
Secondary 8 kV – 16 mA
Kerosene, maximum pressure 10 bar (145 psi)
Gas oil, maximum pressure 15 bar (218 psi)
2
/s at 20 °C
(Hi = 11.97 kWh/kg)
2
/s at 20 °C  (Hi = 11.86 kWh/kg)
9
5
4
GB
8
501 T3K
2 - 3.2 kg/h
24 - 38.3 kW
1
Tab. A
2
6
7
Fig. 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

RdbRdb1 70Rdb1 9035130103513210

Table of Contents