Electrical Connection; Gas Connection - AccuTemp EDGE ALTLGB Owner's Manual And Installation Instructions

Gas-fired insulated self-contained tilting/stationary kettle
Table of Contents

Advertisement

Section I: Installation

Electrical Connection

WARNING: Electrical Grounding Instructions
 This appliance is equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do no cut or remove
the grounding plug from this plug.
AVERTISSEMENT: Mise à la terre
Cet appareil est pourvu d'une fiche à trois broches
dont une mise à la terre assurant une protection contre
les chocs électriques. La prise dans laquelle elle esst
branchée doit être correctement mise à la terre. Ne pas
couper ni enlever la broche de mise à la terre de la fiche.
 Also, it is required that an electrical cut-off device,
such as a fused disconnect switch or equivalent, be
installed in the power supply line between the main
power supply and the unit.
 The pilot flame on this equipment is lit automatically
and requires electrical power to operate. The unit will not
operate if the power is off.
A power cord is provided on the back of the unit, for
connecting to the electric power supply. The installer
should verify the electrical requirements of the unit to
make sure your power supply line is capable of powering
the equipment properly. This information is listed on the
unit's nameplate.
Standard 120 Volt Model: Connect a 120-volt, 60 Hz,
single (1) phase power cord.
Optional 240 Volt Model: Connect a 240-volt, 60 Hz,
single (1) phase power cord.

Gas Connection

WARNING:
 Your installation must conform to local codes or in
the absence of local codes, with the current National Fuel
Gas Code ANSI Z223.1/NFPA 54 (latest edition), or the
National Gas and Propane Installation Code, CSA B149.1
(latest edition), as applicable.
 Do not store or use gasoline or other liquids with
flammable vapors in the vicinity of this equipment.
 Always disconnect the fuel source before servicing.
 The ignition system controls of this equipment have
been factory set for either natural (manufactured) or LP
gas. Do not attempt to use an ignition system control set
for natural (manufactured) gas with LP gas or an ignition
system set for LP gas with natural (manufactured) gas.
Ignition system controls cannot be field converted from
one gas type to the other.
 It is your responsibility to post, in a prominent
location, instructions to be followed in the event the
user smells gas. This information must be obtained
from your local gas supplier.
1. Shut off the main gas supply
before
beginning
the
connection.
2. Properly configure the gas
supply line to be used (see Fig.
1.2). The gas supply line must
be a minimum of 3/4" npt pipe.
It is your responsibility to ensure
that the supply line installed
is large enough to achieve
the proper pressure and allow
the required volume of gas to
flow.
A sediment trap must
be installed to protect against
contamination of the ignition
system control. Install a manual
shut-off valve between the gas
supply line and the sediment
trap to allow for maintenance of
the trap.
Fig. 1.2 Configuration of Gas Connection
3. In making the connections, use a good quality joint
compound. If LP gas is supplied, a joint compound
resistant to LP gas should be used. Connect the supply
line to the ball valve at the rear of the unit. Tighten the
connection securely.
gas
5