Makita DTWA070 Instruction Manual page 9

Hide thumbs Also See for DTWA070:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Changing the parameter setting on the tool (Field Setting mode)
This function is available by default. If you have disabled the Field Setting mode on the computer, enable
NOTICE:
this function beforehand. Refer to the instruction manual of "Makita Industry Tool Settings" for how to configure.
If the Field Setting mode is disabled, making settings on the tool is not available. When you press the
NOTICE:
setting button, the values set on the tool are displayed in order.
The current setting number is displayed on the indicator.
Every time you press the setting button, the indicator shows torque level, rundown level, workable time range, and "Ad".
► Fig.7: 1. Setting button 2. Indicator
You can change the following parameter settings on your tool:
Auto-stop setting / Free mode
Setting item
Torque level
Rundown level
Workable time range
If "OP" (Loosening Auto Stop mode) is displayed on the indicator, torque level setting and rundown
NOTICE:
level setting is not available. In this case, change the mode to Tightening Auto Stop mode, and then set the torque
level and rundown level on the computer using "Makita Industry Tool Settings".
Changing the torque level
When changing the torque level from 23 to 34
► Fig.8
1.
Press the setting button several times until the
indicator shows 2-digit number which stands for
the current setting of the torque level.
2.
Press and hold the setting button until the number
in the tens place starts blinking.
3.
Set the number in the tens place by pressing the
setting button briefly. Every time you press the
setting button, the indicator shows the number
from "0" to "4" and "F" in a cycle.
4.
Press and hold the setting button until the number
in the ones place starts blinking.
5.
Set the number in the ones place by pressing the
setting button briefly. Every time you press the
setting button, the indicator shows the number
from "0" to "9" and "F" in a cycle.
Press and hold the setting button for a few seconds.
6.
NOTE: If you are not sure which torque level is suit-
able for your work, set "FF" so that the tool operates
in the Free mode.
NOTE: If you input "00", "FF" is displayed instead of "00".
Changing the rundown level
When changing the rundown level from L1 to L2
► Fig.9
1.
Press the setting button several times until the
indicator shows 2 characters beginning with "L"
followed by a number. This stands for the current
setting of the rundown level.
2.
Press and hold the setting button until the indica-
tor starts blinking.
Display on the indicator
01 - 40
FF
OP
L1 - L7
OP
Lo: 0.1 - 9.9
HI: 0.1 - 9.9
-.-
3.
4.
Changing the shortest workable time
range
When changing the shortest workable time range
from 2.5 to 3.6
► Fig.10
1.
2.
3.
4.
5.
6.
NOTE: When you set the value smaller than "0.1" for
the shortest workable time range, the indicator shows
"-.-" and the shortest workable time range becomes
disabled. To input "-.-", set the value to "0.9", and then
press the setting button when the number in the ones
place is blinking.
9 ENGLISH
The torque level at which the Tightening
Auto Stop mode works
The sensitivity of the fastener seating
The shortest/longest duration of the rota-
tion when you continue to pull the switch
trigger.
Set the rundown level. Every time you press the
setting button, the indicator shows from "L1" to
"L7" in a cycle. The lowest rundown level is "L1"
and "L7" is the highest.
Press and hold the setting button for a few seconds.
Press the setting button several times until the
indicator shows "Lo" and number alternatively.
This stands for the current setting of the shortest
workable time range.
Press and hold the setting button until the number
in the ones place starts blinking.
Set the number in the ones place by pressing the
setting button briefly. Every time you press the
setting button, the indicator shows the number
from "0" to "9" in a cycle.
Press and hold the setting button until the number
in the decimal place starts blinking.
Set the number in the decimal place by pressing
the setting button briefly. Every time you press the
setting button, the indicator shows the number
from "0" to "9" in a cycle.
Press and hold the setting button for a few
seconds.
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dtwa100Dtwa140Dtwa190

Table of Contents