Does not operate at all.
□ Has there been a power outage?
In this case, the unit restarts automatically after the power supply
is resumed. (Refer to page 10.)
□ Has the circuit breaker been turned off?
⇒ Turn on the circuit breaker.
□ Has a fuse blown out or the circuit breaker been tripped?
⇒ Replace the fuse or reset the circuit breaker.
□ Is the timer operating?
⇒ To check or deactivate the timer setting, refer to page 6.
Poor cooling or heating performance.
□ Is the unit operating under the conditions except the permissible
temperature range?
In this case, the air conditioner may stop because of the automatic
protection circuit working.
□ Is the air fi lter dirty?
⇒ Clean the air fi lter. (Refer to page 9.)
□ Is the intake grille or outlet port of indoor unit blocked?
⇒ Remove the obstructions.
□ Is the room temperature adjusted appropriately?
⇒ To change the temperature setting, refer to page 5.
□ Is a window or door left opened?
⇒ Close the window or the door.
□ Is the fan speed set to Quiet?
⇒ To change the fan speed, refer to page 5.
□ Has the Outdoor Unit Low Noise operation been set?
⇒ To stop the Outdoor Unit Low Noise operation, refer to page 8.
□ <In the Cooling mode> Is direct or strong sunlight shining into the
room?
⇒ Close the curtains.
□ <In the Cooling mode> Are there other heating apparatus or com-
puters operating, or too many people in the room?
⇒ Turn the heating apparatus or computers off, or set the tem-
perature lower. (Refer to page 5.)
Airfl ow is weak or stops.
□ Is the fan speed set to Quiet?
⇒ To change the fan speed, refer to page 5.
□ Has the Fan Control for Energy Saving set? In this case, the
indoor unit fan may stop temporarily while the Cooling operation.
⇒ To cancel the Fan control for energy saving, consult authorized
service personnel. (Refer to page 5.)
□ <In the Heating mode> Have you just started the operation?
In this case, the fan rotates at very low speed temporarily to warm
up the internal parts of the unit.
□ <In the Heating mode> Is the room temperature higher than the
set temperature?
In this case, the outdoor unit stops and the indoor unit fan rotates
at very low speed.
□ <In the Heating mode> Is [ ] indicator blinking?
In this case, the Automatic defrosting operation is working. The in-
door unit stops for maximum of 15 minutes. (Refer to page 10.)
□ <In the Dry mode> The indoor unit operates at low fan speed to
adjust the room humidity, and may stop from time to time.
□ <In the Auto mode> While the monitoring operation, the fan
rotates at very low speed.
Noise is heard.
□ Is the unit operating, or immediate after stopping operation?
In this case, refrigerant fl owing sound may be heard. It may be
particularly noticeable for 2-3 minutes after starting operation.
□ Do you hear a slight squeaking sound during the operation?
This sound is produced by the minute expansion and contraction
of the front panel caused by temperature change.
□ <In the Heating mode> Do you hear a sizzling sound?
This sound is produced by the Automatic defrosting operation.
(Refer to page 10.)
Smell coming from the unit.
□ The air conditioner may absorb various smells generated from
interior textile, furniture, or cigarette smoke. These smells may be
emitted during the operation.
En-13
Mist or steam is emitted from the unit.
□ <In the Cooling or Dry mode> A thin mist may be generated by
condensation formed with sudden cooling process.
□ <In the Heating mode> Is [ ] indicator on the indoor unit blinking?
In this case, steam may rise from the outdoor unit because of the
Automatic defrosting operation. (Refer to page 10.)
Outdoor unit emits water.
□ <In the Heating mode> The outdoor unit may emit water gener-
ated by the Automatic defrosting operation. (Refer to page 10.)
The unit operates differently from the remote controller setting.
□ Are the batteries in the remote controller exhausted?
⇒ Replace the batteries.
Operation is delayed after restart.
□ Has the power supply turned from Off to On suddenly?
In this case, the compressor will not operate for about 3 minutes
to prevent a blowout of the fuse.
Immediately stop operation and turn off the electrical breaker in
following cases. Then consult authorized service personnel.
• The problem persists even if you perform these checks or
diagnostics.
• On the indoor unit, [ ] and [
NOTES: For any troubleshooting related to the WLAN control, refer
to the setting manual for WLAN adapter or the mobile app
installed in your smartphone or tablet PC.