Panasonic SXC09 3E5 Series Installation Manual page 7

Air-to-water heatpump indoor unit
Table of Contents

Advertisement

RCCB/ELCB
*1
Holder
(Clamper)
Power Supply Cord
Terminal screw
Tightening torque cN•m {kgf•cm}
M4
M5
*1 - Earth wire must be longer than other cables for safety reasons
WIRE STRIPPING AND CONNECTING REQUIREMENT
Wire stripping
Indoor/outdoor
connecting
terminal board
No loose strand
when insert
Conductor
Conductor
fully insert
over insert
ACCEPT
PROHIBITED
CONNECTING REQUIREMENT
For SXC09*3E5/SXC12*6E5
The equipment's power supply 1 complies with IEC/EN 61000-
3-12 provided that the short circuit power S
equal to 1700kW at the interface point between the user's supply
and the public system. It is the responsible of the installer or user
of the equipment to ensure, by consultation with the distribution
network operator if necessary, that the equipment is connected
only to a supply with a short short circuit power S
or equal to 1700kW.
The equipment's power supply 1 complies with IEC/EN 61000-3-
11 and shall be connected to a suitable supply net work, having
service current capacity  100A per phase. Please liaise with supply
authority that the service current capacity at the interface point is
suffi cient for the installation of the equipment.
The equipment's power supply 2 complies with IEC/EN 61000-3-12.
The equipment's power supply 2 complies with IEC/EN 61000-3-11
and shall be connected to suitable supply network, with the following
maximum permissible system impedance Z
interface. Please liaise with supply authority to ensure that the power
supply 2 is connected only to a supply of that impedance or less.
INSTALLATION OF REMOTE
7
CONTROLLER AS ROOM
THERMOSTAT
Remote Controller 3 mounted to the Indoor Unit can be moved to
the room and serve as Room Thermostat.
Installation Location
Install at the height of 1 to 1.5 m from the fl oor (Location where
average room temperature can be detected).
Install vertically against the wall.
Avoid the following locations for installation.
1. By the window, etc. exposed to direct sunlight or direct air.
2. In the shadow or backside of objects deviated from the room
airfl ow.
3. Location where condensation occurs (The Remote Controller
is not moisture proof or drip proof.)
Terminal Board
*1
Connecting Cable
157~196 {16~20}
196~245 {20~25}
5mm or
more
(gap between
wires)
Conductor not
fully insert
PROHIBITED
is greater than or
sc
greater than
sc
= 0.271 at the
max
4. Location near heat source.
5. Uneven surface.
Keep distance of 1 m or more from the TV, radio and PC. (Cause
of fuzzy image or noise)
Remote Controller Wiring
Indoor unit
Remote Controller wiring
(fi eld supply)
No polarity
Terminal for Remote Controller wiring
Remote Controller cable shall be (2 x min 0.3 mm²), of double
insulation PVC-sheathed or rubber sheathed cable. Total cable
length shall be 50 m or less.
Be careful not to connect cables to other terminals of Indoor Unit
(e.g. power source wiring terminal). Malfunction may occur.
Do not bundle together with the power source wiring or store in the
same metal tube. Operation error may occur.
Remove The Remote Controller From Indoor Unit
1. Remove the top case from the bottom case.
2. Remove the wiring between Remote controller and Indoor Unit
terminal. Remove the bottom case from the Control board cover
by loosening the screws. (3 pieces)
Claw
(2 places)
Disconnect the
Remote controller
wiring
Remote Controller
1
2
Insert the
driver and
slightly turn.
Flat-blade
screwdriver
Bottom
case
7

Advertisement