041_03
Installation, operating and
maintenance instructions
GAS FRYERS
ADC0009 · ADC0010
ADC0008 · ADC0003
AEC0009 · AEC0010
AEC0011 · AEC0012
04/2006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADC0009 and is the answer not in the manual?

Questions and answers

Summary of Contents for mastro ADC0009

  • Page 1 041_03 04/2006 Installation, operating and maintenance instructions GAS FRYERS ADC0009 · ADC0010 ADC0008 · ADC0003 AEC0009 · AEC0010 AEC0011 · AEC0012...
  • Page 2 INDEX Models and dimensions Note for the installer page page Running the appliance on other types Data of appliances of gas Replacing the main burner nozzle Technical data Replacing the pilot burner nozzle Maintenance Operating instructions Replacing parts Construction, equipment installed Gas valve and safety devices Safety thermostat...
  • Page 3 Dimensions 13.5 13.5 52.5 52.5 52.5 52.5 1/2” gas connector Safety thermostat Technical data Oil drain 041 - 03 - Gas fryers...
  • Page 4 Dimensions ADC00009 ADC00010 ADC00008 ADC00003 3/4” gas connector Safety thermostat Technical data Oil drain 041 - 03 - Gas fryers...
  • Page 5 Dimensions AEC00009 AEC00010 AEC00011 AEC00012 3/4” gas connector Safety thermostat Technical data Oil drain 041 - 03 - Gas fryers...
  • Page 6: Characteristics Of The Appliances

    2 - CHARACTERISTICS OF THE APPLIANCES The instructions contained in this manual apply to our Gas deep fat control panel. It contains all necessary reference data such as the fryer in the II2H3+ category (see table on page 7). name of the manufacturer, input pressure, gas type setting, etc. The data plate is located on the front of the appliance and on the CAT/KAT GAS/GAZ...
  • Page 7 TABLE 1 Model ADC00009 ADC00010 ADC00008 ADC00003 AEC00009 AEC00010 AEC00011 AEC00012 II2H3+ Category Construction type Air necessary for combustion Nominal thermal power 18.0 12.0 24.0 Minimum thermal power Connection pressure Methane gas 2H 20 mbar Liquid gas 3+ G30/G31 28/37 mbar Gas connection values 0.952 1.904...
  • Page 8: Installation

    OPERATING INSTRUCTIONS Construction, equipment installed and - worksheet “Technical rules for installing gas”; safety devices - worksheet “Technical rules for LP gas”; Robust steel frame, with 4 legs (adjustable in height). 18/10 chrome-nickel steel outer panelling and tanks. - worksheet “Gas installations in industrial kitchens”; The oil is heated by means of stainless burners (2 per tank), built to withstand thermomechanical stress.
  • Page 9: Commissioning The Appliance

    screws; - Insert extension (B) onto the collector; - Place part (C) on part (A) and fix with self-tapping screws; - Fit back element (D) onto part (A) and fix. - connect the outlet (E) to the fume exhaust pipe. COMMISSIONING THE APPLIANCE Before commissioning the appliance If you wish to check the nominal capacity further, you...
  • Page 10 Note for the installer - Explain and demonstrate to the user how the machine works according to the instructions and hand him this manual. - Remind the user that any structural alterations to the room housing the appliance may affect the combu- stion air supply.
  • Page 11: Replacing Parts

    REPLACING PARTS Burner (Fig. 1) Unscrew nozzle (28) and nut (29). Loosen the screws (26) fixing the burner to the chamber. Replace the burner. All parts must be replaced by authorised technicians Thermocouple (38 - Fig. 1) only! To replace the following parts, remove the control panel Unscrew the nipple fixing the thermocouple to the valve, (after unscrewing its fixing screws).
  • Page 12: Using The Appliance

    USING THE APPLIANCE Warning! Lighting the pilot burner - Beware of inexpert handling! Press the button (14) and as the same time the piezoelec- - Old and dirty oil or frying fat can represent a real fire tric lighter (12) to light the pilot flame, which can be seen hazard;...
  • Page 13: Emptying The Tank

    Emptying the tank TAKING CARE OF THE APPLIANCE FREQUENCY OF MAINTENANCE When emptying, check that you have a container large enough to collect all the oil in the tank. Warning! The container should be placed correctly under the drain tap. Never clean the appliance with jets of water, whether It is advisable to filter frying oil and fat daily and to chan- direct or pressurised.