Installation (continued)
7
Adjusting the CO2 Regulator
□
Make sure that the shut-off valve (17) is closed (sideways =
closed, down = open), then slowly turn the main valve
on the CO2 tank counterclockwise until it is fully open.
□
Release the adjustment lock nut (18), behind the regulator
adjustment knob (19), by turning it counterclockwise about
5-7 turns.
□
Turn the regulator adjustment knob (19) clockwise to increase
pressure. The needle on the gauge (20) starts to climb. Set the
gauge to 10-12 PSI.
NOTE:
pressure to a lower pressure, you will need
to release the higher pressure by pulling the
manual pressure release valve ring (16)
located on the bottom right of the regulator.
□
Open the shut-off valve (17) to allow gas to ow into the keg.
□
When the tank is at the correct pressure, tighten the
adjustment lock nut (18) by turning it clockwise.
□
Allow several minutes for the keg to pressurize.
The gauge (20) may show a drop in pressure while this
happens. Adjust as needed.
□
Plug the kegerator/beverage cooler into a 120V, 60Hz,
15 Amp grounded outlet.
When adjusting pressure from a high
18
9
Please contact 1-855-847-7264 for further assistance.
20
19
17
HOMEDEPOT.COM
16