INSTALLATION,
OPERATION &
MAINTENANCE
GUIDE
Headquarters
291 Hurricane Lane
Williston, VT 05495
TEL: (802) 878-8307
FAX: (802) 878-2479
STYLE 58
Brazil
Rua Javaés, 441/443
Bom Retiro, Sao Paulo
Brazil CEP 01130-010
TEL: 55-11-3736-7373
FAX: 55-11-3736-7355
Gulf Coast
1719 South Sonny Avenue
Gonzales, LA 70737
TEL: (225) 484-0007
FAX: (225) 341-8922
Texas
Houston
7545 E. Orem Drive
Houston, TX 77075
TEL: (832) 804-7424
Odessa
801 S. Pagewood Avenue
Suite 2, Odessa, TX 79761
TEL: (432) 300-0167
REVISED: September 2022

Advertisement

loading

Summary of Contents for Flexaseal 58

  • Page 1 INSTALLATION, OPERATION & MAINTENANCE GUIDE STYLE 58 Headquarters Brazil Gulf Coast Texas Houston 291 Hurricane Lane Rua Javaés, 441/443 1719 South Sonny Avenue Williston, VT 05495 Bom Retiro, Sao Paulo Gonzales, LA 70737 7545 E. Orem Drive Brazil CEP 01130-010...
  • Page 2 NOTICE Flexaseal does not assume responsibility for misuse, or any damages incurred as a result of the misuse of the supplied sealing system. Contact a Flexaseal representative before making any changes to the provided system or design.
  • Page 3 Installation, Operation, & Maintenance Guide Style 58 PREPARATION edges, and set screw damage using fine emery • Verify that equipment has been properly cloth. Wipe clean. shut off and rendered inoperative according Avoid making flat spots or reducing the to plant safety protocol (e.g. lockout/tagout shaft diameter.
  • Page 4 Installation, Operation, & Maintenance Guide Style 58 VERIFICATION Successful operation of a Style 58 Single Heavy Duty Stationary Multi-Spring Cartridge Seal is contingent on conforming equipment dimensions and alignment. Verify the following prior to continuing: Figure 2: Shaft Runout Figure 3: Bearing Fit...
  • Page 5: Seal Installation

    Installation, Operation, & Maintenance Guide Style 58 SEAL INSTALLATION The Style 58 is a highly engineered, heavy duty 3. Ensure the shaft and seal housing have been stationary multi-spring cartridge seal. It entails the properly cleaned as described in the same simple installation procedure as other preparation section.
  • Page 6: Before Starting The Equipment

    Installation, Operation, & Maintenance Guide Style 58 BEFORE STARTING THE EQUIPMENT 1. Ensure the pump shaft is properly aligned at 6. Ensure all plumbing and venting are free of the coupling with the motor. obstruction and that the chamber is filled with liquid.
  • Page 7: Removing The Seal

    Installation, Operation, & Maintenance Guide Style 58 REMOVING THE SEAL • Before opening the pump to remove the seal the warning stated above regarding toxins and hazardous products must be reiterated. Make note of all fluids contained in the pump, drain and decontaminate before opening the housing for seal service.
  • Page 8 SEAL PRODUCTS Flexaseal Engineered Seals and Systems, LLC (hereinafter referred to as "FAS") warrants that new goods manufactured by FAS (with the exception of "wear parts" or consumables all of which are not warranted) will be free from defects in material and workmanship (the “Warranty”).