Quick Links

INSTALLATION,
OPERATION &
MAINTENANCE
GUIDE
Headquarters
291 Hurricane Lane
Williston, VT 05495
TEL: (802) 878-8307
FAX: (802) 878-2479
STYLE 63 & 66
Brazil
Rua Javaés, 441/443
Bom Retiro, Sao Paulo
Brazil CEP 01130-010
TEL: 55-11-3736-7373
FAX: 55-11-3736-7355
Gulf Coast
1719 South Sonny Avenue
Gonzales, LA 70737
TEL: (225) 484-0007
FAX: (225) 341-8922
Texas
Houston
7545 E. Orem Drive
Houston, TX 77075
TEL: (832) 804-7424
Odessa
801 S. Pagewood Avenue
Suite 2, Odessa, TX 79761
TEL: (432) 300-0167
REVISED: September 2022

Advertisement

loading

Summary of Contents for Flexaseal 63

  • Page 1 INSTALLATION, OPERATION & MAINTENANCE GUIDE STYLE 63 & 66 Headquarters Brazil Gulf Coast Texas 291 Hurricane Lane Rua Javaés, 441/443 1719 South Sonny Avenue Houston Williston, VT 05495 Bom Retiro, Sao Paulo Gonzales, LA 70737 7545 E. Orem Drive Brazil CEP 01130-010...
  • Page 2 NOTICE Flexaseal does not assume responsibility for misuse, or any damages incurred as a result of the misuse of the supplied sealing system. Contact a Flexaseal representative before making any changes to the provided system or design.
  • Page 3 Document how the seal chamber is 5. The maximum surface finish of sealing disassembled for re-assembly. surfaces and the shaft or sleeve must be 63 2. Carefully remove the existing sealing device, Ra-µin as seen in Figure taking care not to damage the shaft.
  • Page 4 Style 63 & 66 VERIFICATION Successful operation of a Style 63 or Style 66 Single High Temperature Welded Metal Bellows Cartridge Seal is contingent on conforming equipment dimensions and alignment. Verify the following prior to continuing: Figure 2: Shaft Runout...
  • Page 5: Seal Installation

    Installation, Operation, & Maintenance Guide Style 63 & 66 SEAL INSTALLATION Style 63 & 66 single high temperature bellows seals The seal will be shipped from Flexaseal require a similar installation procedure as other with the drive collar cap screws finger-tight.
  • Page 6 Installation, Operation, & Maintenance Guide Style 63 & 66 Figure 8: Step Figure 9: Step Figure 10: Step Figure 11: Style 63 layout with steam deflector and floating bushing. Figure 12: Style 66 layout. Page 5 of 8...
  • Page 7: Before Starting The Equipment

    Installation, Operation, & Maintenance Guide Style 63 & 66 BEFORE STARTING THE EQUIPMENT 1. Ensure the pump shaft is properly aligned at 6. Ensure all plumbing and venting are free of the coupling with the motor. obstruction and that the chamber is filled with liquid.
  • Page 8: Removing The Seal

    Installation, Operation, & Maintenance Guide Style 63 & 66 REMOVING THE SEAL • Before opening the pump to remove the seal the warning stated above regarding toxins and hazardous products must be reiterated. Make note of all fluids contained in the pump, drain and decontaminate before opening the housing for seal service.
  • Page 9 SEAL PRODUCTS Flexaseal Engineered Seals and Systems, LLC (hereinafter referred to as "FAS") warrants that new goods manufactured by FAS (with the exception of "wear parts" or consumables all of which are not warranted) will be free from defects in material and workmanship (the “Warranty”).

This manual is also suitable for: