Page 1
INSTALLATION, OPERATION & MAINTENANCE GUIDE STYLE 60/62/65 Headquarters Brazil Gulf Coast Texas 291 Hurricane Lane Rua Javaés, 441/443 1719 South Sonny Avenue 7545 E. Orem Drive Williston, VT 05495 Bom Retiro, Sao Paulo Gonzales, LA 70737 Houston, TX 77075 Brazil CEP 01130-010...
Page 2
NOTICE Flexaseal does not assume responsibility for misuse, or any damages incurred as a result of the misuse of the supplied sealing system. Contact a Flexaseal representative before making any changes to the provided system or design.
Page 3
Installation, Operation, & Maintainance Guide Style 60/62/65 PREPARATION of rust, burrs, grit, sharp edges, and set screw Verify that equipment has been properly damage using fine emery cloth. Wipe clean. shut off and rendered inoperative according to plant safety protocol (e.g. lockout/tagout Avoid making flat spots, reducing shaft...
Page 4
Installation, Operation, & Maintainance Guide Style 60/62/65 VERIFICATION Successful operation of a Style 60/62/65 high temperature rotating welded metal bellows head is contingent on conforming equipment dimensions and alignment. Verify the following prior to continuing: Figure 2: Shaft Runout Figure 3: Bearing Fit...
Page 5
final installation. Style 60/62/65 high temperature bellows rotaries are exclusively intended for inside-mounted use. Do not mount outside of the seal chamber.
Installation, Operation, & Maintainance Guide Style 60/62/65 To scribe the correct locations for the component seal setting length use the following procedure: 1. Reassemble the pump, including the shaft sleeve, seal chamber cover, and impeller as shown in Figure After adjusting the impeller, apply layout dye to the shaft (or shaft sleeve) at the face of the seal chamber,...
Installation, Operation, & Maintainance Guide Style 60/62/65 14. Bolt the gland to the seal chamber using the increments until a gland seal is achieved. Be Legacy Method (Star Pattern) according to sure not to overtighten the gland bolts as this torque requirements specified in the pump...
Installation, Operation, & Maintainance Guide Style 60/62/65 unnecessarily (i.e. shut down and disassembled without cause). Below is an inexhaustive list of possible causes of leakage. Primary Causes Secondary Causes Worn seal faces Change in duty conditions Damaged bellows Dry-running Damaged grafoil packing...
1.875 5.125 2.000 4.125 5.125 2.000 4.250 5.125 2.000 4.375 5.375 2.000 4.500 5.375 2.000 Style 60 & 65 dimensional chart 4.625 5.625 2.000 4.750 5.625 2.000 Bellows Shaft Seal Seal size -16X 1.000 1.562 1.687 ALL DIMENSIONS IN INCHES ALL DIMENSIONS IN INCHES 1.125 1.687...
Page 10
SEAL PRODUCTS Flexaseal Engineered Seals and Systems, LLC (hereinafter referred to as "FAS") warrants that new goods manufactured by FAS (with the exception of "wear parts" or consumables all of which are not warranted) will be free from defects in material and workmanship (the “Warranty”).