c. Touching "
" icon on the 'Basic Info' screen will bring up the 'Alarm' screen.
This screen displays the BMS protection function.
Automatic Safety Shutoff and Restart
BMS Function
Over Charge Voltage
Over Discharge Voltage
Over Charge Current
Over Discharge Current
High Temperature on Charge
High Temperature on Discharge
Low Temperature on Charge
Low Temperature on Discharge
Short Circuit
12
C12-100XLi
Automatic Shutoff
Cell ≥3.7V or Battery ≥14.8V; 3S max Cell ≤3.45V or Battery ≤13.8V
Cell ≤2.5V or Battery ≤10.0V; 3S max Cell ≥2.8V or Battery ≥11.2V
105A for 3S or 138A for 500mS or
284-345A for 17mS
350A for 3S or 560-650A for 8mS
Above 50ºC
Above 65ºC
Below 0ºC
Below -20ºC
Above 1200A, 400 µS
LITHIUM PRO
LITHIUM PRO
LITHIUM
ADVANCED LiFePO4 TECHNOLOGY
Recovery and Automatic Restart
After 13S, up to 3 consecutive times.
Except at >284A, no auto recovery
After 13S, up to 3 consecutive times.
Except at >560A, no auto recovery
Below 45ºC
Below 55ºC
Above 5ºC
Above -15ºC
No automatic recovery
PRO
PRO