Service Diagnosis: Circuit Board - Scotsman TDE470 Service Manual

Scotsman tde470 ice machine: user guide
Table of Contents

Advertisement

TDE470

Service Diagnosis: Circuit Board

Circuit Board Light
Identification
Explanation of Indicator Light or Reset
Will be On after the second auger motor trip, indicating that the
machine must be cleaned and/or inspected for drive train
maintenance and manually reset.
This button must be pushed if the auger motor has overloaded
twice.
On at all times when the master switch is ON and machine is
connected to electrical power.
On when ice level is low (unit making ice).
Normal 6 minute off/delay start. To prevent short cycling, the
machine will not restart after any shut off (excpet power to the
board) until 6 minutes have passed.
Too much current has been drawn thru the auger motor. This
light is ON for the 30 minutes that must pass before the machine
will automatically restart.
After the first Auger Motor Error, the next 60 minutes of operation
are monitored, and this light will be ON. If another Auger Motor
Error occurs, the machine shuts down.
On when water level is low in the reservoir.
Position On
Board
February 1995
Page 22
1
2 - Reset Button
3
4
5
6
7
8
Name and Meaning of
Light or Reset
1
Auger Motor
Overload, ON =
Trouble
2
Auger Motor Reset
Button
3
Power,
ON = Normal
4
Bin Empty,
ON = Needs Ice
5
Off Timer,
ON = Unit cycling off
6
Auger Motor Error,
ON = Trouble
7
Auger Motor Timer,
ON = Trouble
8
No Water,
ON = Trouble

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tde470ae-1aTde470ae-6a

Table of Contents