Function 04 Read Input Register
Register
Parameter
3x0001
Differential pressure
3x0002
Differential pressure
3x0003
Differential pressure
3x0004
Temperature
3x0005
Temperature
3x0006
Relative humidity
3x0007
Relative humidity
3x0008
3x0009
3x0010
Volume flow (high byte)
3x0011
Volume flow (low byte)
3x0012
Dew point
3x0013
Absolute humidity
3x0014
Mixing ratio
3x0015
Enthalpy
3x0016
Air density
Function 05 Write Single Coil
Register
Parameter
0x0001
Auto zero (Differential pressure)
0x0002
System of units
Differential pressure
Volume flow
Temperature
Relative humidity
Dew point
Absolute humidity
Mixing ratio
Enthalpy
Air density
®
814x - Modbus | Telegrams
Without filtering
Filtering
1 s
Filtering 10 s
Sampling
4 s
Filtering 32 s
Sampling
4 s
Filtering 32 s
Computed value
Computed value
Computed value
Computed value
Computed value
Computed value
Computed value
SI
→ Imperial
[Pa]
→ [inWC]
3
[m
/h] → [CFM]
[°C]
→ [°F]
[%RH]
[%RH]
[°C]
→ [°F]
3
[g/m
] → [gr/ft
[g/kg]
→ [gr/ lb]
[kJ/kg] → [Btu/lb]
3
[kg/m
] → [lb/ft
Data Type
Signed 16 Bit
Signed 16 Bit
Signed 16 Bit
Signed 16 Bit
Signed 16 Bit
Signed 16 Bit
Signed 16 Bit
Unsigned 16 Bit
Unsigned 16 Bit
Signed 16 Bit
Signed 16 Bit
Signed 16 Bit
Signed 16 Bit
Unsigned 16 Bit
Data Type
Bit 0
Bit 1
3
]
3
]
24
Value
Range
– 5000...+ 5000
– 500.0...+ 500.0 Pa
– 7000...+ 7000
– 7000...+ 7000 Pa
– 2000...+ 2000
– 2.000...+ 2.000 inWC
– 2813...+ 2813
– 28.13...+ 28.13 inWC
– 5000...+ 5000
– 500.0...+ 500.0 Pa
– 7000...+ 7000
– 7000...+ 7000 Pa
– 2000...+ 2000
– 2.000...+ 2.000 inWC
– 2813...+ 2813
– 28.13...+ 28.13 inWC
– 5000...+ 5000
– 500.0...+ 500.0 Pa
– 7000...+ 7000
– 7000...+ 7000 Pa
– 2000...+ 2000
– 2.000...+ 2.000 inWC
– 2813...+ 2813
– 28.13...+ 28.13 inWC
– 350... +800
– 35.0... +80.0 °C
– 310...+1760
– 31.0...+176.0 °F
– 350... +800
– 35.0... +80.0 °C
– 310...+1760
– 31.0...+176.0 °F
0...1000
0.0...100.0 % RH
0...1000
0.0...100.0 % RH
0...99
Value* 10000 m
0...99
Value* 10000 CFM
0...9999
0...9999 m
0...9999
0...9999 CFM
0... 500
0.0... +50.0 °C
320...1220
+32.0...+122.0 °F
0...800
0.0...80.0 g / m³
0...349
0.0...34.9 gr / ft³
0... 800
0.0... 80.0 g / kg
0...5600
0.0...560.0 gr / lb
0...850
0.0...85.0 kJ / kg
0...360
0.0...36.0 Btu / lb
500...1600
0.500...1.600 kg/m
312... 998
31.2 ... 99.8 lb/ft³
Value
Range
0 / 1
OFF - ON
0 / 1
SI (Default) -
Imperial
3
/h
3
/h
3

Advertisement

loading

This manual is also suitable for: